Standard or Nonstandard: | Standard | Structure: | Other, Thermostatic Inserts | Pressure: | Medium Pressure |
Power: | Other, Self-acting | Material: | Brass | Temperature of Media: | Low Temperature |
Media: | Water | Port Size: | DN15,1/2" | Place of Origin: | Liaoning, China |
Model Number: | BXHS-15-M | Brand Name: | SYBX |
Product Description
Specifications
Factory,ISO9001:2008Mixing Valve
Setting Temperature Range: 35-45 C
Idea for Domestic Water Application
Tamper-Proof Cap
1. Technical Data
DN15
a.Working pressure:0.03-1Mpa
b.Ideal working pressure:0.1-0.5Mpa
c.Maximum working temperature:≤99C
d.Hot water inlet temp range:50-80C
e.Cold water inlet temp range:5-29C
f.Outlet Temperature range: 35-45C
g.Adjustment Accuracy:+/-2C
h.Rated outlet flow(1 bar pressure drop):0.7Cb.m./H(Same as 11.67L/Min)
Flow rate for pressure:
Pressure (psi or kPa) | 1 psi | 5 psi (34kPa) | 10 psi (69kPa) | 15 psi (103kPa) | 20 psi (138kPa) | 30 psi (207kPa) |
Flow Rate (liters per minute) | 4.5 | 9 | 12.5 | 15.1 | 17.6 | 28.2 |
GPM | 0.98 | 2.0 | 2.7 | 3.3 | 3.9 | 6.2 |
2.Materials of Construction
a.Valve body:Brass with Ni-Plated
b.Shutter:PPO
c.Spring:Stainless steel
d.O-ring:EPDM
e.Connection:Inlets-M,Outlet-M
3.Features:
a.Fail-safe on Hot or Cold Supply Failure
b.Delivers Stable Mixed Water Temp
c.Extended Mix Temperature Range:35-45C
d.Idea for Domestic Water Application
e.Tamper-Proof Cap
4.What is the thermostatic mixing valve?
A Thermostatic Mixing Valve is a valve that blends hot water (stored at temperatures high enough to kill bacteria) with cold water to ensure constant, safe outlet temperatures preventing scalding.
They shut-off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock.
TMVs accurately control water temperatures for bathing, showering and hand-washing. They maintain pre-set temperatures - even if water pressure varies when other appliances are used. TMVs can be fitted under baths and basins, be part of shower fittings,or as a feature of exposed hot and cold water mixers.
5.Usage of TMVs
Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.
6.Installation Precaution:
a.All installations should be carried out by a Licensed Professional.
b.Install in accordance with markings on valve body. i.e.hot water inlet-marked H, cold water inlet-marked C.
c.After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2C.
d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.
e.If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure.
f.Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation.
7.How They Work?
Upon use of tempered water, a thermostat in the mixing chamber of the valve senses the outlet temperature. The thermostat automatically positions a seat assembly which controls the flow of hot and cold water supplied to the mixing chamber. If the mixed outlet temperature increases, the thermostat will expand moving the seat assembly to allow the cold water inlet port to open more fully and at the same time restricting the hot water inlet port. Conversely,if the mixed outlet temperature decreases, the thermostat will contract moving the seat assembly to allow the hot water inlet port to open more fully and at the same time restricting the cold water inlet port. In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve. In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve.
8.Installation Precaution:
a.All installations should be carried out by a Licensed Professional.
b.Install in accordance with markings on valve body. i.e.hot water inlet-marked H, cold water inlet-marked C
c.After temperature setting,if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2 C.
d.The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.
e.If the ratio between two inlets is too large,one flow-limiting valve should be fixed at the side of higher pressure.
f.Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation
9.Relationsships between TMVs and Legionella:
Legionella is the bacteria responsible for Legionnaires Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacteria and has been found to exist widely in many surface water sources such as; lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system
It can find an ideal host environment of warm water temperatures (40-46Celsius degree), stagnant water areas (storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaires Disease.
There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 60C. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries.
Contact Us
- Shenyang Beixin Energy Saving Equipment Co., Ltd.
- Contact nameYan Zhang Chat Now
- Phone86-24-22510528
- AddressBlock B, #18-11, Yaoyang Road, Huishan Agricultural Hi-Tech Zone Shenyang,Liaoning
- Solar collector thermostatic mixing valve
- Solar energy water heater thermostatic mixing valve
- Solar water heater Thermostatic mixer
- Thermostatic mixer valve
- solar collector valve
- Wash Basin Valve
- Thermostatic Valve
- thermostatic mixing valves for solar system made in China
- Thermostatic Mixing Valve
- Thermostatic Valve
- Solar geyser thermostatic mixing valve
- Thermostatic Mixing Valve for solar heater(DN15)
Popular Searches
Recommended Products
- Ductile Iron Restrained Flange Adaptor Coupling for HDPE Pipes with Brass Ring
- Ductile Iron Tapping Saddles for PVC Pipes
- Ductile Iron Wide Range 4'' Universal Flexible Joint Coupling For Steel DI CI PE PVC Pipe
- Double Balls Screwed Thread End Rubber Expansion Joint
- Ductile Iron Epoxy Coating Wide Range Universal Coupling Joint For DI Pipe
- Stainless Steel Water Pipe Single/Double Band Repair Clamp For CI, DI, Steel,PE And PVC Pipe
- Factory Price Ductile Iron Cast Iron Pipe Fitting Flexible Flange Adaptor Coupling for PE Pipe
- Plumbing Fittings Pipe Support Clamps Pipe Repair Clamp
- Stainless Steel Band Type Repair Clamp For Large Diameter Pipe
- Stainless Steel 304 Flange Metallic Bellows Expansion Telescopic Joint
- Epoxy Powder Coating Ductile Iron Flexible Flange Adaptor and Dresser Coupling for HDPE Pipe
- PVC Pipe Elbow Stainless Steel Repair Clamps
Find Similar Products By Category
- Mechanical Parts & Fabrication Services > Valves
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Yan Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile