Uc 1000V Photovoltaic DC Solar Energy 40kA Surge Protector
- 50000 Set / Sets per Month
- Conton/shanghai
- T/T L/C D/P D/A Credit Card PayPal
Product Details
Place of Origin: | Hunan, China | Brand Name: | ZHONGPU SHENGDE | Model Number: | DXH06-F/3DC800R40 |
Product Description
1. APPLICATION
Designed especially for surge protection of the PV strings; apply to the PV power grid-connection system.
2.TECHNICALS PARAMETERS
Model DXH06-F/ | 3DC1000R40 | 3DC800R40 | 3DC600R40 | |
Type (IEC 61643-1) | Class II /Type 2 | |||
Max. Continuous Operating Voltage(Uc) | 1300VDC | 1000VDC | 800VDC | |
Nominal Continuous Operating Voltage(Un) | 1000VDC | 800VDC | 600VDC | |
Nominal Discharge Current Capacity (In) | 20kA(8/20μs) | |||
Max. Discharge Current Capacity (Imax) | 40kA(8/20μs) | |||
Protection Mode | Full Mode Protection | |||
Protection Level(Up) | ≤4.0kv | ≤3.6kv | ≤3.2kv | |
Response Time(T) | <25ns | |||
Fault Indicator | Available | |||
Live Line(mm² ) | ≥6 | |||
Earth line(mm² ) | ≥10 | |||
Grounding Resistance(R) | ≤4Ω | |||
Protection Level of the Shell | IP20 | |||
Operating Temperature | -40℃~+70℃ | |||
Overall Size(mm) | 54×90×65 | |||
Installation Method | 35 mm DIN-rail |
3.NAMING RULES:
4. WIRING DIAGRAM
5.Main Features:
l Use Y-shaped connection, Full mode protection of the L+-L-/PE;
l Use the temperature control circuit break protection technology,to avoid the accident;
l With the remote alarm contact signal, convenient to remote monitoring of the system;
l The module has normal and fault indication, with fast response speed and low residual voltage.
6.Installation Method and Attentions
1) Wiring as shown in Figure;
2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;
3) The front of lightning arrester shall be connected with proper fuse in series or be opened;
4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;
5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;
6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;
7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.
7. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan Chat Now
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park Zhuzhou,Hunan
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
- 24V Combined 3 in 1 Signal Lightning Protection
- 24V Combined 3 in 1 Signal Lightning Surge Protector
- 24V Combined 3 in 1 Signal Under Voltage Protector
- 24V Combined 3 in 1 Signal Lightning Arrester
- 24V Combined 3 in 1 Signal Lightning Protection Device
- 220V Signal Lightning Protector
- Network Surge Protection Device
- 50kA 10/350us CLASS I Wind Power Generation Lightning Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation Surge Protection Device
- 50kA 10/350us CLASS I Wind Power Generation Surge Arrester
- 50kA 10/350us CLASS I Wind Power Generation SPD
- 50kA 10/350us CLASS I Wind Power Generation Lightning Protection Device
- 50kA 10/350us CLASS I Wind Power Generation AC Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation 440V Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation Lightning Arrester
- 50kA 10/350us CLASS I Wind Power Generation Under Voltage Protector
- 50kA 10/350us CLASS I Wind Power Generation Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation Lightning Protection
- Class II N-PE Wind Power Generation Surge Protection Device
- Class II N-PE Wind Power Generation Outdoor Surge Protector
- Class II N-PE Wind Power Generation AC Surge Protector
- Class II N-PE Wind Power Generation 690V Surge Protector
- Class II N-PE Wind Power Generation Surge Protector
- Class II N-PE Wind Power Generation Lightning Arrester
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- ABB PM902F 3BDH001000R0001 CPU Module
- ABB TU811V1 3BSE013231R1 Compact Module Termination Unit
- EPRO PR6423/01R-040 CON021 Eddy Current Sensor
- Bently nevada 330101-00-34-10-02-05 3300 XL 8 mm Probe
- Bently Nevada 330103-00-10-05-02-00 Proximity Probes
- SIEMENS 6DD1662-0AB0 Interface and communication modules
- EPRO PR6423 015-000 CON021 Sensor Module
- Siemens 6DD1642-0BC0 Analog Output Module
- SIEMENS 6DD1640-0AC0 Simatic I/o Module
- SIEMENS 6DD1611-0AF0 mm3 plc module
- SIEMENS 6DD1611-0AD0 MEMORY MOSULE SIMADYND PROCESSOR
- SIEMENS 6DD1610-0AG1 memory module
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile