Product Details
Place of Origin: | Hunan, China | Brand Name: | ZHONGPU SHENGDE | Model Number: | DXH06-AVC/24 |
Product Description
1. APPLICATION:
This kind of SPD has lots of excellent characteristics, such as low residual voltage, small fading, easy installation and large discharge current capacity. It can protect the power supply, video signal, control part and network of the equipment.
The product is applicable to the video signals of monitoring system, video display, cable TV and home TV for the purpose of protecting the sensitive video lines and of preventing them from being damaged by the induced lightning overvoltage, power interference, and static discharge.
2. NAMING RULES:
3. TECHNICALS PARAMETERS
Model DXH06- | AVC(AN)/24 | ||
Target to be protected | Power Supply | Video part | Control part |
Interface Type | 3P Terminal | BNC | 2P Terminal |
Max. Continuous Operating Voltage (Uc) | 40VAC | 8V | 24V |
Protection Level(Up) | ≤170V | ≤20V | ≤40V |
Load Current(I) | 5A |
|
|
Insert Loss (dB) |
| ≤0.2dB | ≤0.2dB |
Nominal Discharge Current Capacity(In) | 5kA(8/20μs) | ||
Max. Discharge Current Capacity(Imax) | 10kA(8/20μs) | ||
Grounding Resistance(R) | ≤4Ω | ||
Protection Level of the Shell | IP20 | ||
Operating Temperature | -40℃~+70℃ | ||
Overall Size(mm) | 132×75×47 |
4. Installation Method and Attentions
1. Confirm the interface and connecting way.
2. SPD must be wired in series between signal channel and the protected device.
3. The input (IN) of the lightning protector shall be connected with the signal channel, and the output (OUT) shall be with the protected device. They can’t be confused.
4. The grounding shall be reliable and the earth line shall be as short, coarse and straight as possible for purpose of reducing the influence of distributed electric inductance on the discharge of thunder & lightning.
5. No special maintenance is needed for the lightning protector. In case of a fault during the operation, the lightning protector can be dismantled. After that, if the system is operated normally, it is necessary to replace the lightning protector.
5. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan Chat Now
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park Zhuzhou,Hunan
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
- 50kA 10/350us CLASS I Wind Power Generation SPD
- 50kA 10/350us CLASS I Wind Power Generation Lightning Protection Device
- 50kA 10/350us CLASS I Wind Power Generation AC Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation 440V Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation Lightning Arrester
- 50kA 10/350us CLASS I Wind Power Generation Under Voltage Protector
- 50kA 10/350us CLASS I Wind Power Generation Surge Protector
- 50kA 10/350us CLASS I Wind Power Generation Lightning Protection
- Class II N-PE Wind Power Generation Surge Protection Device
- Class II N-PE Wind Power Generation Outdoor Surge Protector
- Class II N-PE Wind Power Generation AC Surge Protector
- Class II N-PE Wind Power Generation 690V Surge Protector
- Class II N-PE Wind Power Generation Surge Protector
- Class II N-PE Wind Power Generation Lightning Arrester
- Class II N-PE Wind Power Generation Lightning Protection
- Class II N-PE Wind Power Generation Lightning Protection Device
- Class II N-PE Wind Power Generation 30kA Surge Protector
- Class II N-PE Wind Power Generation Surge Protection
- Class II N-PE Wind Power Generation SPD
- Class II N-PE Wind Power Generation Lightning Surge Protector
- Class II N-PE Wind Power Generation Surge Arrester
- Class II N-PE Wind Power Generation Lightning Protector
- Class II N-PE Wind Power Generation Under Voltage Protector
- 48V DC 40kA lightning arrester price
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- Woodward 31902-02 accessories Suppliers and Company
- Woodward 1720-015 31902-02 4-314871-1 accessories Suppliers and Company
- Woodward 8200-1301 505 Turbine Control Panel
- Woodward 9905-760 PLC Module/Rack
- Woodward 9905-204 Speed Regulator
- Woodward 9905-971 LINKNET 16 CHANNEL DISCRETE INPUT MODULE REV J
- Woodward 9905-970 Rev K, LINKNet, 6 Channel 100 Ohm RTD
- Woodward 9905-969 Linknet Module 6 Channel
- Woodward 8516-039 TG-13 GOVERNOR
- Woodward 8444-1092 Multifunction Relay with CANopen / Modbus Communication
- woodward 8440-1809 CONTROLLER EASYGEN-1500
- High Speed Pulse 8CH Digital Input Module Supports SNMP Modbus RTU/TCP MQTT
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile