Home > Products > Air Handling Unit > Air Handling Unit with Glycol Heat Recovery for Hospital
Air Handling Unit with Glycol Heat Recovery for Hospital
- 100000 Set / Sets per Month
- Tianjin Port
- China High Purification Chilled Water Air Handler
- Double Panel Air Handling Unit with Heat Recovery
- Industrial Air Handling Units, DX Air Handling Unit, Expert Design, good price
- Fresh Air Handling Unit, High Efficiency, Low Noise, Commerical and Industrial Use
- Horizontal Cabinet Air Handling Unit, with Heat Recovery
- Industrial Air Handling Unit with Heat Recovery, Used in Car Manufacturer Factory
Product Details
Place of Origin: | Beijing, China | Brand Name: | Holtop | Model Number: | HJK |
Type: | Other, HVAC Systems, Chilled water AHU |
Packaging Details
Seaworthy wooden cases
Product Description
Specifications
Double panelsSkin thickness of 25mm~50mm
Chilled water type
Multi-functions
Heat Recovery: Glycol
Introduction of Air Handling Unit with Glycol Heat Recovery
1) Vertical or Ceiling type
2)Multi-functional
3)Heat recovery functions (Eurovent Heat Exchanger)
4)Excellent thermal insulation
5) Airflow 2000~100000CMH
Main features
1) Equipped with supply fan and exhaust fan, brings in fresh air and exhausts out stale indoor air as well.
2) Equipped with rotary heat exchanger, recovers energy from outgoing indoor air, to save operating cost to the max.
3) Thin height, easily installed in the ceiling space.
Housing construction
1) Double skin panel
25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high density fireproof PU with thermal coefficient below 0.0199W/m Degree.
2) High air tightness
Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3%.
Supply fan and exhaust fan
Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level.
Filter
Plate type(G4) coarse filter as standard configuration. (Bag filter F5~F8 available as per request of customer). Draw-push installation, easy maintenance.
Eurovent Rotary heat exchanger
Holtop total heat exchanger (enthalpy recovery wheel) is made of aluminum foil coated with 3A molecular sieve, which enables the wheel to exchange both temperature and humidity, in another word, to recover both sensible and latent heat.
Operation and maintenance
1. AHU is powered by TN-S power supply system, i. E. AC3~380V+N+PE.
2. Check and make sure motor runs at right direction and freely. Run the unit after all the electric parts are checked without fault by a professional.
3. Commissioning is required before putting the equipment into use. Motors should be running under rated electric current.
4. Cooling & heating coil should use clean demineralized water as medium, working pressure ≤ 1.2MPa.
5. Drain out the water in the coil in winter, and blow away the remains water as far as possible. In case remains water can not be blew away, inject antifreeze into the coil.
6. Examine the filter regularly, clean or replace it if resistance comes to the end resistance. Air-dry the washed fil- ter totally before reuse.
7. Fully clean or maintain the unit after each 1 or 2-year operation. Clean the coils using compressed air or high pressure water.
Company Profile
Founded in 2002, we are a famous air to air heat exchanger equipment manufacturer in China. Our company is located in Baiwang Mountain Forest Park that is famous for "Oxygen Source of Beijing", with construction area of 30,000 square meters. Yearly production quantity reaches 100,000 sets. We have been dedicating to researching and developing air heat exchange technology since setting up. We were one of the main companies engaged in editing national standard "GB/T 21087-2007 air to air energy recovery equipment" in 2007 and "unit type ventilation air to air heat recovery units for air condition" in 2013.
We master air heat exchange core technology. We independently develop various kinds of heat exchangers such as plate, rotary, heat pipe type and liquid circulation type etc. and use the heat exchange technology developing heat recovery ventilator and combining heat recovery air handling units, wind turbine air to air heat exchange coolers etc., which are widely applied to healthy green house, commercial central air condition, industrial purification central air condition, wind turbine, basement station cooling system etc. Our products sell in native and export to 41 foreign countries and areas. Heat recovery ventilator and heat exchanger rank top one in native market share.
Contact Us
- Beijing Holtop Artificial Environment Technology Co., Ltd.
- Contact nameLynn Zhang Chat Now
- Phone86-10-59798831-626
- AddressNo. 158, Hanjiachuan
Product Categories
Accessories | Air Handling Unit | Climate Unit | Fresh Air Handling Unit |
Heat Pipe Heat Exchanger | Heat Recovery Ventilator | New Products | Plate Heat Exchanger |
Rotary Heat Exchanger |
- Pharmaceutical Factory Air Handling Unit, Low noise
- Ceiling Suspended Air Handling Unit, with Plate Heat Exchanger
- HEPA Air Handling Unit Chilled Water DX Coil Optional
- Air Treatment Plant with Eurovent Rotary Heat Exchanger
- Air Treatment Plant with Rotary Heat Exchanger, Plate Heat Exchanger
- Holtop modular heat recovery air handling unit
- Holtop Chilled Water Modular Air Handling Unit
- Fresh Air Handling Unit with Heat Recovery
- Car Industry FAHU with HRW
- Hospital Use FAHU with Energy Saving Component
- Fresh Air Handling Unit
- Gym Use FAHU with Energy Saving Component
- Mushroom Use FAHU with Energy Saving Component
- Washhouse Use Heat Recovery Air Handling Unit
- hvac Air Handling Unit system
- AHU hvac system
- Clean Operation Room Air Handling Unit
- Air Handling Unit (modular type)
- Horizontal and Vertical Cabinet Air Handling Unit (AHU)
- high efficiency low noise industrial air handling units
- Ceiling Mounted Air Handling Unit, Cabinet Air Handling Unit (AHU)
- Broken cold bridge heat recovery air handling unit
- CE certified chilled water hygienic air handling unit
- Central air handling units
Find Similar Products By Category
- Construction & Real Estate > HVAC Systems & Parts
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lynn Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile