Home > Products > 5. LV Current Transformer > 80/5A Class 1.0 Current Transformer
80/5A Class 1.0 Current Transformer
- 100000 Piece / Pieces per Month
- Ningbo or Shanghai
- T/T L/C D/P D/A Credit Card PayPal
Product Details
Place of Origin: | Zhejiang, China | Brand Name: | YOMIN | Model Number: | MSQ-30-80/5 |
Usage: | Current | Phase: | Single | Coil Structure: | Toroidal |
Coil Number: | Other, 16 turns |
Product Description
80/5A Class 1.0 Current Transformer
Model: MSQ-30-80/5-CL1.0
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They're connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT.
- Measuring CT: Measuring current transformers are constructed to feed on other low voltage apparatus such as measuring instruments, relays, watt-hour meter (KW meter) and these type of current transformers are mainly used 0.5 and 1.0 class to transfer the current from highest rated current to rated secondary current.
- Protection CT: Protection current transformers are constructed to feed the protection relay. These type of current transformers are mainly used 5P. (Customer supplied when required.)
Selection of the Current Transformer
To select the current transformer correctly, the following points should be clarified:
- -The application (for measuring or protection).
- -The features of the working environment (Indoor or outdoor, operating temperature, air humidity etc….).
- -Operation voltage and frequency.
- -Range of the primary current (maximum and minimum of the current to be measured).
- -Dimension of the cable or Bus bar.
- -Data of the overload.
- -Short circuit current.
- -Specification of the measuring device associated with the current transformer (Accuracy, rated current, consumption etc…).
- -The diameter and length of the cable, the cable which is used to connect the current transformer and associated measuring device.
Power Losses of the CT
In the practical application, the power generated by the primary current should be equal or bigger than the power requirement of the associated measuring device plus the consumption of the connecting line.
Losses in the line, PL:
This is the power loss, through heat, generated by current through the resistance RL in the cable, in the transformer’s secondary circuit.
Factors to be taken into account:
Secondary current: PL = RL / 2
Cable diameter: RL is inversely proportional to the square of the diameter cable length: RL is proportional to the length of cabling (there and back).
Power: The nominal apparent power (VA) with a specified power factor, which was supplied by the Current Transformer, to the secondary current with the assigned current when it is connected to its nominal load. Sc (VA) = Zc (/sn)2 According to Standards, for apparent power greater than or equal to 5VA, the power factor is 0.8 inductive. For apparent power less than 5VA the power factor is considered to be one (unity).
Accuracy of A Current Transformer
The percentage of error, produced in a transformer, is established by IEC60044-1. In measurement transformer: 25% and 100% of nominal power. In protection transformers: 100% of nominal power.
Note: with…/1A transformers losses are reduced 25 times.
Saturated Condition of CT
The current transformer is saturated if the primary current, passing through the CT, is greater than the nominal rating of the CT.
The linearity of CT, between the primary and secondary sides decreases, so error increases. The saturation of the CT is inversely proportional to the load (FIG. 1).
The difference between measuring and protection current transformers is their behavior when an overload occurs on the primary side. Measuring CT is saturated when there is a primary current overload. In order to protect the equipment. On the secondary side, protection CT will not saturated until there is a very high current on the primary side, A class 5P15 protection transformer indicates that it has an accuracy rating of ±1% that it does not become saturated until the primary current reaches 15 times the nominal current rating of the CT.
In measuring transformers, the SAFETY FACTOR “FS” parameter indicates the excessive amperage on the primary side current in relation to the current sent to the measuring device on the secondary side.
Application Note
If the primary current is too small, to keep the same accuracy and output, we can add primary winding, but the rated turns ration should be the same, For example, if the primary current is 50A, we can use 100/5A current transformer with the primary current be turned twice which help to keep the same rated turns ratio (1:50 = 2:100).
Construction
CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.
- Current Ratio..................................................................................80/5A
- Accuracy.........................................................................................Class 1.0
- Burden.............................................................................................See Selection Form.
- Security Factor................................................................................FS<5
- Max System Voltage.......................................................................720V AC
- Test Voltage.....................................................................................3kV AC. (1 min.)
- Frequency........................................................................................50/60Hz
- Rated Short-time Thermal Current (Ith)........................................Ith = 60 X In
- Rated Dynamic Current (Idyn).......................................................Idyn = 2.5 X Ith
- Continuous Overload.....................................................................1.2 X In
- Working Temperature....................................................................-25°C ~ +50°C
- insulation Rating.............................................................................Class B
- Housing Self-extinguishing Class.................................................VO
- Bus-bar Support Mounting.............................................................Provided
- Panel Mounting................................................................................Provided
- Hinged Sealable Terminal Cover....................................................Provided
- Standards.........................................................................................IEC/EN60044-1, VDE0414-44-1, BS3938, BS7626
Item | Current Ratio | Rated Burden (VA) | Case Qty. | |
Model | (A) | Class: 0.5 | Class: 1.0 | (Pcs) |
MSQ-30 | 30/5 | - | 1.5 (3T) | 60 |
MSQ-30 | 40/5 | - | 1.5 (2T) | 60 |
MSQ-30 | 50/5 | - | 2.5 (2T) | 60 |
MSQ-30 | 60/5 | - | 2.5 (2T) | 60 |
MSQ-30 | 75/5 | - | 1.5 | 60 |
MSQ-30 | 80/5 | - | 1.5 | 60 |
MSQ-30 | 100/5 | - | 2.5 | 60 |
MSQ-30 | 150/5 | - | 3.75 | 60 |
MSQ-30 | 200/5 | 5 | 5 | 60 |
MSQ-30 | 250/5 | 5 | 7.5 | 60 |
MSQ-30 | 300/5 | 10 | 10 | 60 |
Note:
Class and VA rating must be mentioned when ordering.
Contact Us
- Yueqing Yomin Electric Co., Ltd.
- Contact nameLinda Chat Now
- Phone0086-577-61616259
- AddressQiaoqian Village, Liushi Town, Yueqing
- 150/5A Class 0.5 Current Transformer
- 40/5A Class 1.0 Current Transformer
- 750/5A Class 0.5 Current Transformer for Metering
- 1200/5A Class 0.5 Current Transformer (Indoor)
- 1200/5A Class 0.5 Current Transformer for Measuring
- 1600/5A Class 1.0 Current Transformer
- 2000/5A Class 0.5 Current Transformer (Indoor)
- 1250/5A Class 1.0 Current Transformer
- 1250/5A Class 0.5 Current Transformer
- 800/5A Class 0.5 Current Transformer (Indoor)
- Good Quality 1200/5A Class 0.5 Split Core Current Transformer CT, Current Transformer/
- Manufacturer PVC taping MR-60 Current Transformer 500/5A, Cuttent Transformer/
- Manufacturer 550VA Toroidal Transformer ,Power Audio Isolation Transformer .
- Manufacturer 100VA Control Transformer ,With Terminal Blocks Transformer.
- Manufacturer 150VA Control Transformer , RBK Series Copper Transformer .
- Manufacturer 250VA Control Transformer ,BK Single Phase Transformer .
- Manufacturer 1000VA Control Transformer (Foot Mounting) , Electricity Transformer .
- Manufacturer 400VA Machine Tool Control Transformer,Isolation Transformer Quality Choice
- Manufacturer BK Series 220 V 24V Machine Tool Transformer, Control Power Transformer Capacity100VA Quality Choice
- Manufacturer BK Series Control Transformer , Single Phase Isolation Transformer 40VA . Quality Choice
- Manufacturer 120VA International Typical Transformer , Isolation Transformer .
- Manufacturer 25VA International Typical Transformer , Single Phase Transformer / Quality Choice
- Manufacturer 50VA International Typical Transformer , Single Phase Transformer .
- Manufacturer 63VA International Typical Transformer , Isolation Transformer.
Popular Searches
- power transformer
- Distribution Service
- current transformer
- power transformers
- High Frequency Transformer
- Electrical Transformer
- energy saver device
- led transformers
- step up converter
- Ac Drive Converter
- Frequency Drive Converter
- electronic transformer
- Lighting Transformers
- toroidal transformer
- auto transformer
- current transformer inductor
Recommended Products
- KCT-816 Split Core Current Transformer Window Type 160*80mm
- 5A output Busbar Split Core Current Transformer for Monitoring Devices
- KCT-816 2500:5A Busbar type split core current transformers
- RS1000-1500A/333mV Open Close Three-Phase Flexible Rogowski Coil Current Transformer
- Flexible Rogowski Coil Current Transformer for Measuring High Current AC Signals
- Cheap Price Finely Processed Series Epoxy Resin Cast Power Dry-Type Transformer
- Electrical Power Distribution Epoxy Resin Cast Dry Type Isolation Transformer
- Factory Direct Price Three-phase Step-down Transformer Furniture Transformer Price
- High Performance Three-Phase AC Industrial Dry Type Iron Core Reactor dry type
- Manufacturer Supplier Epoxy Resin Dry Type Transformer three phase 11kv 33kv
- Popular Recommend Three phase transformer dry type transformer
- Professional Factory Three phase transformer dry type transformer
Find Similar Products By Category
- Electrical Equipment & Supplies > Transformers
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Linda
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile