Home > Products > Daily morning check box for hipot tester > Hipot Inspection Box
Hipot Inspection Box
- 5000 Unit / Units per Month
- SHANGHAI
Product Details
Place of Origin: | Jiangsu, China | Brand Name: | Allwin | Model Number: | CS26032 |
Protection Level: | Other | Type: | Control Box | External Size: | 12.9cm*4.5cm*5.9cm |
Product Description
Specifications
Check the hipot tester each time prior to start work everyday morning and do some relevant records.Purpose:In order to make the tester run normally and the test meet the product standard
Check the hipot tester each time prior to start work everyday morning and do some relevant records.
Voltage:2000V
Cut off current:1.0mA
Accuracy :2%
The hipot inspection box can be designed by the customers' requirements
For example:
Voltage:1000V
Cut off current:1.0mA
Voltage:5000V
Cut off current:1.0mA
The main technical parameters:
Voltage: 2000V; Leak Current: 1mA; Time:≤10s
- Purpose:In order to make the tester run normally and the test meet the product standard
- Scope: Check the hipot tester
- Operation steps:
1. Check the hipot tester each time prior to start work everyday morning and do some relevant records.
2. The high pressure resistance is 2.0kV/1mA
2.1 High voltage check
2.1.1 Connect the HV inspect box to the hipot tester
2.1.2. Turn on the power switch. Set the output voltage as 2000V, the leakage current high-limit as 1.1mA, lower-limit current as 0.9mA,set the test time should be less than 10s.
2.1.3. Start to test, if the tester do not alarm, the tester is good. If the test is failed, please trace back the measuredproduct. The details are as following list:
Voltage | High-limit of leak current | Low-limit of leak current | Phenomenon | Judgment | Result |
2.0kV | 1.10mA | 0.90mA | Alarm | fail | Trace back the measured product |
Do not alarm | Pass | Tester is normal |
- If the wrong running check is appeared, please trace back the last product that has been detected, and after the calibration to the hipot tester, re-test the product, and record the test results in the inspection list.
- After calibration, if the re-test results meet the requirements, then proceed to do the next step.
- During the high voltage running inspection process, when the tester is alarming, but there is no beeper sound or the super leakage indicator (Failed indicator) is not lit, the hipot tester may be damaged. When the hipot tester is broken down, user should stop using the broken hipot tester and stick the label as "suspended" to the tester. Notify the engineering department for maintenance and deliver it to the nationally recognized testing laboratories. Trace back all the components have been tested, and use the qualified hipot tester to do the dielectric strength and the insulation test again.
- Precautions:
1.The operator should wear insulated leather gloves and stand on the insulated leather to prevent electric shock.
2. The tester must be grounded well
3. User must ensure that the high-voltage output "0" and at the "stop" state before connect the DUT.
4. The tester ground and the DUT ground should be reliably connected. Open-circuit is rejected.
5. The ground of the output should not be short circuit with the AC power.
6. Avoid the short circuit between the high voltage output terminal and the ground.
7. Once the test light, ultra leakage light is damaged, it must be replaced immediately, to avoid causing a miscarriage of justice;
8. Cut off the power before troubleshooting.
Contact Us
- Nanjing Allwin Instrument Science And Technology Co., Ltd.
- Contact nametruda mao Chat Now
- Phone86-025-68132208
- AddressNo.10 Feiying Road, Jiangning Binjiang Economical Development Zone, Nanjing, China Nanjing,Jiangsu
- CS9950N 32A output current 510mohm Programmable ground resistance tester
- CS9950DS earth resistance tester
- CS9950CS earth resistance tester
- CS9950AS earth resistance tester
- CS9950S earth resistance tester
- 40A output current 600mohm resistance Programmable ground resistance tester
- Programmable ground resistance tester
- 60A CS9950EC DC Programmable Grounding Resistance Tester
- 40A CS9950EA DC Programmable Grounding Resistance Tester
- 30A CS9950E DC Programmable Grounding Resistance Tester
- Ground Continuity Tester(VFD display)
- 30A Programmable Grounding Resistance Tester
- Ground Continuity Tester
- Programmable Grounding Resistance Tester
- 40A Programmable Grounding Resistance Tester CS9950CX
- Programmable Grounding Resistance Tester
- Grounding Resistance Tester
- Ground Bond Tester Earth resistance tester
- CS9922M Programmable withstanding voltage Insulation resistance tester
- CS9922N 5kV AC/6kVDC Dielectric Strength Tester,Insulation Resistance Tester hipot tester insulation test AC DC high voltage Quality Choice
- CS9922AN 5kV AC high voltage Dielectric Strength Tester,Insulation Resistance Tester AC hipot tester insulation resistance test
- Programmable withstanding voltage tester
- Programmable Hipot/ Insulation Resistance tester
- Programmable Insulation / Withstanding Voltage Tester
Popular Searches
- lighting box
- Power Box
- Electronic & Instrument Enclosures
- metal enclosures
- electrical box
- enclosure box
- Electronic Instrument Box Enclosure
- Plastic Enclosure
- Electronic Instrument Control Enclosure
- Junction Box
- Outdoor Junction Box
- Waterproof Junction Box
- Din Rail Project Box
- Abs Plastic Enclosure
- Surface Box
- Fuse Box
Recommended Products
- Bently Nevada 330104-00-12-10-02-00 Extension Cable sensor
- ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
- ABB FAU810 signal amplifier
- Allen-Bradley 1768-L43 CompactLogix L43 2MB Memory Controller
- 6ES7322-1HF01-0AA0SiemensSIMATIC S7-300 Digital Output module SM 322 Potential isolated 8 digital outputs (relays) 24V DC, 2A
- 6ES7322-1HF10-0AA0SiemensSIMATIC S7-300 Digital Output Module SM 322 8 digital outputs (relays) 24V DC
- 6ES7231-7PC22-0XA0SiemensSIMATIC S7-200 analog input module EM 231 is used for the S7-22X CPU 4AE
- 6ES7231-7PB22-0XA8SiemensSIMATIC S7-200 CN analogue input EM 231, for S7-22X CPU
- 6ES7231-0HF22-0XA0SiemensSIMATIC S7-200 Analog input module EM 231 for the S7-223 CPU 8 Analog input 0-10V DC
- 6ES7231-0HC22-0XA8SiemensSIMATIC S7-200 CN analog input module EM 231, only for S7-221 CPU 4 AE 0-10V DC
- 6ES7223-1PM22-0XA8SiemensSIMATIC S7-200 CN, digital module I/OEM 223 for S7-223 CPU 32 DE 24V DC
- 6ES7223-1BM22-0XA8SiemensSIMATIC S7-200 CN, digital module I/OEM 223 for S7-223 CPU 32 DE 24V DC
Find Similar Products By Category
- Electrical Equipment & Supplies > Electronic & Instrument Enclosures
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
truda mao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile