Place of Origin: | Guangdong, China | Brand Name: | INVT | Model Number: | HT1115L |
Phase: | Single Phase | Protection: | Short Circuit | Weight: | 20KG |
Output Voltage: | 220V/230V/240V | Type: | On-line | Application: | Computer |
Product Description
Specifications
1.single phase UPS;6~20kVA2.high input PF(0.99) and output PF(0.9),
3.low THDi, high efficiency
4.big LCD display.
HT1106S | HT1106L | HT1110S | HT1110L | HT1115L | HT1120L | |
INPUT | ||||||
Cold Start | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | ||
Acceptable Input Voltage | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | ||
100% load@80%~125% | 100% load@80%~125% | 100% load@80%~125% | 100% load@80%~125% | |||
90% load@70%~80% | 90% load@70%~80% | 90% load@70%~80% | 90% load@70%~80% | |||
80% load@60%~70% | 80% load@60%~70% | 80% load@60%~70% | 80% load@60%~70% | |||
65% load@50%~60% | 65% load@50%~60% | 65% load@50%~60% | 65% load@50%~60% | |||
Phase | Single phase in,single phase out | Single phase in,single phase out | Three phase in,single phase out | Single phase in,single phase out | ||
Transfer Voltage Range | ||||||
-Line low transfer | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | ||
-Line low recovery | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | ||
-Line high transfer | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | ||
-Line high recovery | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | ||
Input Power Factor | ≥0.99 | ≥0.99 | ≥0.98 | ≥0.98 | ||
Input Frequency Range | 40Hz - 70Hz | 40Hz - 70Hz | 40Hz - 70Hz | 40Hz - 70Hz | ||
Generator | Support Any Generator | Support Any Generator | Support Any Generator | Support Any Generator | ||
OUTPUT | ||||||
Frequency adaptable | Settable | Settable | Settable | Settable | ||
Power | ||||||
-Power(kVA) max | 6 | 10 | 15 | 20 | ||
-Power(kW) max | 5.4 | 9 | 13.5 | 18 | ||
Output Voltage | ||||||
-Waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | ||
-Nominal voltage | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | 220/230/240VAC | ||
-Voltage regulation | ± 1 % | ± 1 % | ± 1 % | ± 1 % | ||
-Transient response | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ||
-Transient recovery | ≤15ms (0% - 100% -0%) | ≤15ms (0% - 100% -0%) | ≤15ms(0% - 100% -0%) | ≤15ms(0% - 100% -0%) | ||
-Voltage distortion | ≤1% THD, linear load | ≤1% THD, linear load | ≤1% THD, linear load | ≤1% THD, linear load | ||
≤ 5% THD, non-linear load | ≤5% THD, non-linear load | ≤5% THD, non-linear load | ≤5% THD, non-linear load | |||
Output Frequency | ||||||
-Synchronization range | settable,±3Hz default | settable,±3Hz default | settable,±3Hz default | settable,±3Hz default | ||
-Slew rate | 0.5~5Hz/s,2 Hz/s default | 0.5~5Hz/s,2Hz/s default | 0.5~5Hz/s,2Hz/s default | 0.5~5Hz/s,2Hz/s default | ||
-Battery mode | (50±0.05) Hz | (50±0.05) Hz | (50±0.05) Hz | (50±0.05) Hz | ||
Transfer Time | ||||||
-Line mode to battery mode | 0 | 0 | 0 | 0 | ||
-Inverter to bypass | 0.1ms | 0 | 0 | 0 | ||
Efficiency | ||||||
-Line mode with battery full charged | 93.0% | 93.0% | 93.5% | 93.5% | ||
-ECO mode | 98.0% | 98.0% | 98.0% | 98.0% | ||
-Battery mode | 92.0% | 92.0% | 92.0% | 92.0% | ||
Noise | <48dB@<70%load,<58dB@>70%load;1m away | <48dB@<70%load,<60dB@>70%load;1m away | 53dB@<70%load,<66dB@>70%load;1m away | 53dB@<70%load,<66dB@>70%load;1m away | ||
Overload Capability (Line Mode) | 110%: Transfer to bypass after 60 mins. | 110%: Transfer to bypass after 60 mins | 110%: Transfer to bypass after 60 mins | 110%: Transfer to bypass after 60 mins | ||
130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | |||
150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | |||
Overload Capability (Battery Mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | ||
125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | |||
>125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | |||
Crest Ratio | 3:1 | 3:1 | 3:1 | 3:1 | ||
BATTERY | ||||||
Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
Quantity | 16 | 16 | 16 | 16 | ||
DC Voltage | 192VDC | 192VDC | 192VDC | 192VDC | ||
Back-up Time | 4mins @80% load | Depend on the capacity of external batteries | 3.5mins @80% load | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
Battery-Low Voltage | (176±3)VDC | (176±3)VDC | (176±3)VDC | (176±3)VDC | ||
Charger | ||||||
-Charging voltage | (220±1%)VDC | (220±1%)VDC | (220±1%)VDC | (220±1%)VDC | ||
-Charging current (max) | 1A | 5A | 1A | 5A | 5A | 5A |
-Charging time | 7h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries | Depend on the capacity of external batteries | Depend on the capacity of external batteries |
Leakage current | <1mA | <1mA | <1mA | <1mA | ||
INDICATOR & ALARM | ||||||
Display | LED+LCD | LED+LCD | LED+LCD | LED+LCD | ||
Alarm | Sounding once per second | Sounding once per second | Sounding once per second | Sounding once per second | ||
Fault | Continuous beeping | Continuous beeping | Continuous beeping | Continuous beeping | ||
INTERFACE | ||||||
Smart RS232 | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | Standard Cable support INVT Power Monitor Software | ||
Dry Contactor | 5 Ports | 5 Ports | 5 Ports | 5 Ports | ||
SNMP(option) | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | Power Managment from SNMP Manager and Web Browser | ||
OPTION | ||||||
ECO Kit | YES | YES | YES | YES | YES | YES |
Long Parallel Cable | YES | YES | YES | YES | YES | YES |
Parallel Kit | YES | YES | YES | YES | YES | YES |
SNMP | YES | YES | YES | YES | YES | YES |
Contact Us
- INVT Power System (Shenzhen) Co., Ltd.
- Contact nameSarah Zhang Chat Now
- Phone86-755-26782480
- Address1# Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, China Shenzhen,Guangdong
Product Categories
Battery | Inverter | New Products | Telecom Rectifier |
UPS |
New Products
- Offline 400VA~1200VA UPS
- 220V 1-3KVA online UPS
- HT 31/11 6-20KVA online UPS 0.9PF
- 10kVA 3: 1 0.9pf Online UPS
- HT 31/11 6-20KVA online UPS
- HT series Online UPS 6-72KVA
- HT series 6-20KVA online UPS
- 1-3KVA online UPS
- Rack Mounted Online UPS 1-10kVA
- HR Series 1-10kVA Rack Mounted Online UPS
- HT series high frequency online 1-3KVA ups
- maintenance free battery 12V 9Ah
Popular Searches
- data conversion
- Online Ups
- Line Interactive Ups
- home ups
- Ups Power Supply
- Uninterruptible Power Supply
- Backup Power Supply
- Uninterrupted Power Supply
- Ups Network Management Card
- Lighting Server
- Uninterrupted Power Supply (UPS)
- double conversion online ups
- high frequency online ups
- low frequency online ups
- single phase ups
- 1kva online ups
Recommended Products
- Eaton 9PX2000RT UPS power supply 9PX2000RT
- Multi functional network cabinet, server room equipment cabinet, DC cabinet, power cabinet, State Grid power screen cabinet, thickened cabinet
- Computer DC Network Industrial Communication Cabinet Battery 47U Monitoring Power Cabinet National Screen Cabinet Vertical Comprehensive
- Cabinet DC Cabinet Communication Cabinet Distribution Cabinet Industrial Cabinet State Grid Power Panel Cabinet Monitoring Cabinet 47U Server
- Customized high and low voltage complete distribution cabinet, power cabinet, mining lighting electrical box, control cabinet, construction site charging pile distribution box
- State Grid Power Cabinet Communication Server Monitoring Cabinet Power Cabinet Communication Cabinet Integrated Floor standing DC Cabinet
- INVT Tower Online UPS 1-3kVA 2.0 (220V/230V/240V)
- INVT 100-600kVA Modular Online UPS(380V/400V/415V)
- Excitation Regulator Power Supply Module 4NIC-FD360 for thermal power plant
- POE DC UPS for telecom,network,ONU,ONT,CCTV
- Lithium battery UPS,nickel cadmium battery UPS, electricity inverter, outdoor UPS
- Outdoor UPS 1KVA-100KVA with air conditioner, water proof, dust proof, heat proof
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Supplies > Uninterrupted Power Supply (UPS)
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now
INVT Power System (Shenzhen) Co., Ltd.
AIBot OnlineThis conversation is AI-generated. Contact manufacturer before transaction to confirm info.
-
Sarah Zhang
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile