Home > Products > Closed Cooling Tower > 100tons Spiral Cooling Tower
100tons Spiral Cooling Tower
- 600 Set / Sets per Month
- qingdao
- T/T Credit Card
You May Like
Product Details
Condition | New | Cooling Type | Counter Flow | |
Material | Metal | Place of Origin | Shandong, China | |
Brand Name | Heng An Closed Cooling Tower | Model Number | Closed cooling tower | |
Voltage | As Model Closed Type Water Cooling Tower | Power(W) | 110-415v etc | |
Dimension(L*W*H) | As Model Closed Type Water Cooling Tower | Weight | As Model Industrial Closed Circuit Water Cooling Tower | |
Certification | ISO9001:2008 | Warranty | 12 month | |
After-sales Service Provided | Overseas service center available |
Product Description
Spiral Cooling Tower
The closed circuit cooling tower advantage experience
Application in engineering
1.Water-source heat pumps
2.Self-contained cooling units
3.Chilers
4.Free cooling applications
5.Date centers
6.Hybrid evaporative/dry cooling
7.Cooling special fluids
8.Compressor jacket cooling Inter cooling,Aftercooling
9.Machine jacket cooling
10.Induction furnaces
11.Consolidating multiple loads into a single cooling nuit
The closed circuit cooling tower advantage
1.VS.Cooling Tower +Heat Exanger Combination
Closer approach to wet bulb temperature and reduce fouling improve process efficiency
2.VS.Air-Cooled Systems
10-20°C lower process temperatures ,less required space ,and lower energy consumption .
3.VS.Once –Through Systems
Reduces environmental impact ,saving up to 95% of the cooling water .
4.Reduced installed Cost And Space Requirements
Effectively combines the function of a cooling tower and heat exchanger into one piece of equipment ,reduce required piping and system complexity .
Technical parameters
Cooling Tower Total circulating water | 1800m3/h |
Cooling Tower Inlet water temperature | 43°C/33°C |
Cooling Tower Out water temperature | 35°C/25°C |
Wet-bulb temperature | 22°C/16°C |
System Design pressure | 0.2MPa |
Drift circulating water loss | 0.01% |
Cooling tower air intake | sides(inlet side of the barrier-free) |
Process principle of Mixed flow series
Structure and main parts
1.Propeller Fan
2.Spray pump
3.Imported board of Zinc-plate and Aluminum-plate
4.Condensing Coils
5.Electronic Water-Curing Device
6.Set Up Dehydrator
7.Advantage Water Distribution System
8.PVC Wet Deck
Engineering considerations
1.Location
Closed Circuit Cooling Towers must have an adequate supply of fresh air to all inlets.
When units are located adjacent to building walls or in enclosure .Care must be taken to ensure that the warm ,saturated discharge air is not deflected and drawn back to the air inlets .
2.Think on compatibility of liquid (gas)
The fluid to be cooled must be compatible with the coil material .Fluids not compatible with ciol materials can lead to corrosion and tube failure .Certain fluids may require occasional pressure cleaning or mechanical cleaning of the inside of coil tubes .in such cases the coil must be designed to provide this capability .
3.Piping and Valves
Piping must be size and installed in accordance with good piping practice .All piping should be supported by pipe hangers or other supports ,not by the cooling tower .External shut off valves may also be required if the system design necessitates the isolation of individual tower cells .
4.Capacity Control
In general season ,the performance of most closed circuit cooling tower will vary dues to the change of its environmental wet bulb temperature .Therefore ,when the change of environmental temperature leads to the difference of liquid temperature ,in this case ,capacity control will be required .
How to prevent the cooling towers to be freezed
1.Protection Against Basin Water Freezing
2.Protection Against Coil Freezing
Application Fields
1.Towers in Central Air Conditioning
2.Closed Circuit Cooling Towers in Heat Treatment Industry
3.Air Compressor Cooling System
4.Towers in Metallurgy Industry
5.Special Industry
Part of the product photos
Certification
FAQ
(1)Your company is a manufacture or trading company?
We are a leading cooling tower manufacturer for 38 years . It is“famous brand”-Heng An manufacture in China
(2) What is the difference between a "counter flow" and a "cross flow" cooling tower?
The crossflow or counterflow designation characterizes the orientation of the airflow within the heat-transfer media (fill) in the tower with respect to the direction of water flow.
In counterflow towers air travels vertically upwards through the fill and makes intimate contact with water droplets falling down through the fill media. Hence the air and water travel in opposite directions.
In crossflow cooling towers the air passes through the fill media in a horizontal direction, thus crossing the downward water flow. Counterflow towers are inherently more efficient than crossflow towers.
(3) How do I get repair parts and how long does it take?
Complete Parts Workshop, and can supply all parts
90% of Spare parts can be distributed to any place on the world within one week!
Contact Us
- Weifang Heng An Import & Export Co., Ltd.
- Contact nameyan Li Chat Now
- Phone86-536-6103201
- AddressRoom1210,No.4 Building Zuoanhuating No.2613,Yuhe Road Kuiwen District Weifang City Shandong Province, Weifang, Shandong
Product Categories
New Products
-
Closed type Cooling Tower
-
HA BHX-40 Closed cooling tower price
-
HA BHX-50 Closed cooling tower price
-
HA BHX-60 Closed cooling tower price
-
HA BHX-70 Closed cooling tower price
-
HA BHX-85 Closed cooling tower price
-
HA BHX-100 Closed cooling tower price
-
HA BHX-125 Closed cooling tower price
-
HA BHX-150 Closed cooling tower price
-
HA BHX-175 Closed cooling tower price
-
HA BHX-200 Closed cooling tower price
-
HA BHX-225 Closed cooling tower price
Popular Searches
- frp cooling tower
- cooling tower
- water tower
- cooling tower infill
- spray nozzle
- plastic nozzle
- Water Spray Nozzle
- Spiral Spray Nozzle
- Cooling Tower System
- computer tower
- Gas Tower
- water cooling tower
- pp filler
- water nozzle
- cooling nozzle
- Mist Spray Nozzle
- Sprayer Nozzle
- Mixing Nozzle
- Industrial Cooling Tower
- frp cooling water tower
- pvc sheet infill
- aluminum tower
- tower 200
- Counterflow Cooling Tower
- Cooling Tower Fill
- bac
- pvc nozzle
- industrial spray nozzles
- spray nozzles
- Spiral Jet Nozzle
Recommended Products
- high quality Square cooling tower wholesale price
- Good price Industrial FRP Counterflow Round Cooling Tower Supplier
- Good Price FRP Cross Flow industry square cooling tower supplier
- low noise counterflow FRP Industrial round cooling tower for chiller
- Open Type Cross Flow Industrial FRP Square Water Cooling Tower
- Produced by Jinggang Factory Industrial and commercial central air conditioning cooling towers
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for casting cooling
- Produced by Jinggang Commercial central air conditioning cooling tower and DN1400 ammonia synthesis tower
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for quenching production line cooling
- Produced by Jinggang Commercial central air conditioning cooling tower and Cooling tower for industrial furnace cooling
- Galvanized steel water tanks
- biochemical sponge filter
Find Similar Products By Category
- Machinery > Refrigeration & Heat Exchange Equipment > Cooling Tower
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
yan Li
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile