Place of Origin: | Jiangsu, China | Brand Name: | Applent | Model Number: | AT680 |
Display Type: | Digital Only | Measuring Range: | 1nA~20mA, 1kΩ~325GΩ | Testing Voltage: | 198VAC~240VAC/110V |
Accuracy Class: | 1% | Operating Temperature: | 0 - 55 | Dimensions: | 315mm(Width)*230mm(Height)*405mm(Depth) |
Product Description
1. Descriptions
The AT680 Leakage Current/IR Meter provides DC 1~ 650 V voltage source. Mainly used for electrolytic capacitor leakage current testing, and aluminum-foil withstand voltage testing. And also can be used for active voltage checking or leakage current testing of absorber, Zener diode, and Neon lamp etc. RS232C interface and Handler interface, optional USB interface, high speed (55/second) and stable measurement capabilities enable the AT680 can be used for both component evaluation on the production line and fundamental leakage current testing for benchtop applications.
AT680 Leakage Current Meter | |
SPECIFICATIONS | |
Parameters | Leakage current and insulation resistance |
Accuracy | 1% |
Output voltage | NC 1V~650VDC |
Measurement Range | I: 1nA~20mA R:1kΩ~325GΩ |
Max Reading | 9999 |
Range | Automatic and Manual |
Charging Current | 200mA(MAX) |
Speed | 55 times/second,15 times/second,3 times/second |
Result Display | Show, current, resistance, peak value, and sorting result |
Charging Timer | 999.9s |
Comparator | 30 sets record,GD/NG |
Beep | GD,NG,OFF setting and volume setting |
Interface | RS-232 interface Handler interface |
GENERAL FEATURES | |
Power Supply | Voltage: 198VAC~240VAC Frequency: 50Hz Power: Max 50VA |
Dimension & Weight | Outside(mm): 264 (Width)x107(Height)x350 (Depth) Inside (mm): 216(Width)x88(Height)x323(Depth) 5kg |
ORDERING INFORMATION | |
Accessories | ATL507: Test clip ATL603: Test clip ATL108: RS232 interface cable |
2. Company Profile and the main advantages
Changzhou Applent Instruments Inc. was established in 2005, named Applent Technology. In 2009, Applent Technology renamed Applent Instruments Inc. With strong technical team, Applent focus on designing, researching and developing, manufacturing and selling all kinds of electrical meters, such as Precise Resistance Meters, DC Resistance Meters, LCR Digital Electric Bridges, Insulation Resistance Meters, etc.
The main advantages:
A we have strong technical team and focus on designing,researching and developing
B we manufacture and sell all kinds of electrical meters, such as Precise Resistance Meters, DC Resistance Meters, LCR Digital Electric Bridges, Insulation Resistance Meters, etc
C we have a lot of agents all over China and USA Office. Professional people offer specialized technical support.
3. The distribution of export markets and major customers
Our customers
OEM Available
We are looking for distributors and agents from all over the world.
We support Trade Assurance.
Welcome to contact:
Tel: +86 0519-88805550
QQ: 2541966918
Skype: applent_instruments
TradeManager: cn1001223788
Contact Us
- Changzhou Applent Instruments Ltd.
- Contact nameVera He Chat Now
- Phone86-0519-88805550
- Address3 Floor, No. 61, Baolong International, Chahua Road Changzhou,Jiangsu
- Applent Hot Product AT680 Leakage Current Meter for Capacitors Leakage Current Tester
- AT680 Digital Leakage Current Meter and Insulation Resistance Meter
- AT680 Digital Leakage Current Meter for Capacitors
- Hot Sale AT680 Leakage Current Tester with Timing Charger
- Digital Leakage Current Meter Model AT680
- AT680 Leakage Current Meter for Capacitor Leakage Current with RS232 and Handler Interface
- AT680 Digital Leakage Current Tester Leakage Current Meter with RS-232 and Handler
- AT680SE 1V-650VDC Output Voltage Leakage Current Meter
- AT680 Leakage Current Tester Leakage Current Meter with 30 Groups Record
- Hot Sale AT680SE Leakage Current Meter with 2% Accuracy Test Leakage Current
- Digital AT680 Leakage Current Meter
- Insulation Resistance Tester and Leakage Current Tester Model AT680
- AT680 Leakage Current Meter with Current Measurement Range 1nA-20mA
- AT680 Leakage Current Tester and Insulation Resistance Meter with 30 Groups of Record
- AT680 Digital Meter for Capacitor Leakage Current with Measurement Range 1nA~20mA 1kohm~325Gohm
- AT680 Leakage Current Tester with RS232 Interface and Handler Interface
- Digital AT680 Leakage Current Meter Output Voltage 1V-650VDC for Electric Wires
- AT680 Digital Leakage Current Meter Output Voltage1V-650VDC for Electronic Components
- AT6832 Leakage Current Tester 0.1microA-20mA Measurement Range
- AT680 Leakage Current Tester for Capacitor with Current Measurement Range 1nA-20mA Handler and RS-232 Interface
- Hot Product Digital AT680 Leakage Current Meter Output Voltage 1V-650VDC for Capacitor
- Digital AT680 Leakage Current Meter Output Voltage 1V-650VDC for Electric Materials
- AT680 Leakage Current Meter Output Voltage 1V-650VDC for Transistor Leakage Current
- AT680 Leakage Current Tester for Capacitor with Current Measurement Range 1nA-20mA
Popular Searches
Recommended Products
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Acrel AIM-M200 Medical Intelligent Insulation Monitoring Device For IT System ICU CCU With Alarm Output Hospital Isolation
- Insulation Monitoring Device Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Hospital Insulation Monitoring Device Accurate Insulation Resistance Monitoring
- Acrel AIM-M200 Insulation Monitoring Device For IT System/Electric Insulation Monitoring Device
- hospital isolation transformer system insulation monitoring device
- medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- acrel AIM-M200 medical IT system hospital isolation transformer system insulation monitoring device insulation fault locator
- insulation monitoring device for IT systems
- Digital display DC Low Resistance Tester Low value resistance tester
- Digital earth resistance tester ground resistance meter soil resistivity test
- Double clamp grounding resistance tester soil resistivity ground voltage DC voltage and AC current
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Resistance Meters
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Vera He
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile