Home > Products > Earthing Switch > EK6 -12 / 40.5kv Indoor AC High Voltage Earthing Switch For Energy Engineering
EK6 -12 / 40.5kv Indoor AC High Voltage Earthing Switch For Energy Engineering
- 0 Piece / Pieces per Month
- T/T L/C D/P D/A
- 7 days
- Rated Peak Withstand Current 50, 63, 80, 100 KA12kv Electrical Switchgear KYN28A -12
- 12kv Electrical Switchgear For Power Substation / Enclosure IP4X, Door is Open IP2X
- Rated Current 630 - 4000 A 12kv Electrical Switchgear KYN28A - 12 For Power Substation
- 12kv Electrical Switchgear with Advanced Relay - protecting Device Automatically Power
- Full Assembled structure 12kv Electrical Switchger KYN28A - 12, rated frequency 50 / 60 Hz
- GB3906, DL / T40412kv KYN28A - 12 Electrical Switchgear Rated Frequency 50 / 60 Hz
Product Details
Brand Name: | Mingde Electrical | Place of Origin: | China | Model Number: | EK6 |
Product Description
Certification:GB1984, IEC
EK6 -12 / 40.5kv Indoor AC High Voltage Earthing Switch For Energy Engineering
1 Normal Using Ambient Conditions
(a) ambient air temperature: upper limit +40℃
lower limit – 25℃
Remark: allow to store and transport under – 30℃
(b) altitude limit: under 1000m
(c) relative humidity: under 90%
(d) earthquake intensity : not higher than class Ⅷ
(e)the place should be without fire, explode danger, serious dust, chemical corrosion and strong shork.
2 Technical Parameters
Model |
Rated voltage (kV) |
Highest working voltage (kV) |
4S rated short time withstand curren(kA) |
Rated dynamic stable current (peak value) (kA |
Making current(peak value) (kA) |
Pole centers (mm) |
Making speed (m/s) |
Main circuit contact resistence (μΩ) |
|
EK6-12/31.5-210 |
10 |
12 |
31.5 |
80 |
80 |
210 |
﹥6 |
<120 |
|
Ek6-40.5/31.5-280 |
35 |
40.5 |
31.5 |
80 |
80 |
280 |
﹥6 |
<120 |
|
Remark:the pole centers can be changed according to customers’ requirement
3 Summary
Earthing switches of series EK6 are determined for indoor installation and conform to the requirements of GB1985 and IEC 62271-102. They are fitted with snap-action operating mechanisms for positive high-speed closing and sufficiently dimensioned to conduct the rated short-circuit making current when closed under load. The speed of the snap-action closing operation is independent controls. The earthing switches are supplied as kits with a pre-assembled active part and correspon ding earthing con tacts supplied loose. Correct in stallation of these parts in a switchgear panel results in a functioning earthing switch. Routine tests toGB1985 and IEC 62271-102 are to be carried out at site accordingly.
Contact Us
- Ningbo Mingde Electrical Science&Technology Co., Ltd
- Contact nameAlec Sun Chat Now
- Phone86-574-63287928
- Address151Huapeng Road,Kandun Industrial Park,Cixi Ningbo zhejiang Liaocheng,Shandong
- 7.2 ~ 12kV 3 Phase AC50 / 60Hz Single Busbar Sectional Power System Electrical Switchgear
- Completely Metal - Clad and Enclosed 12kv Electrical Switchgear for Power Substation
- Distribution Equipment 24kv Air - Insulated Metal - Clad Enclosed High Voltage Switchgear
- High Precision, Anticorrosion 24kv High Voltage Switchgear KYN28A - 24 / GB3906, DL / T404
- OEM KYN28A - 24 24kv High Voltage Switchgear with High Intensity Excellent Nuts and Bolts
- 3 - Phase AC50 / 60Hz High Voltage Switchgear for Power Generator, Substation, Factory
- Rated Peak Withstand Current 50, 63, 80KA 24kv High Voltage Switchgear
- OEM Rated Voltage 24kv High Voltage Switchgear / Main Busbar Rated Current 630 - 4000 A
- Rated Short time Withstand Current 20, 25 KA 24kv High Voltage High Voltage Switchgear
- Circuit Breaker Pole Conductance Circuits Assembly Links, Lower Circuit Resistance
- Miniaturization Shorten Distance Vacuum Circuit Breaker Pole
- Circuit Breaker Pole Fully Satisfy Requirements of GB / DL of Secondary Filthy Area
- Epoxide Resin Vacuum Circuit Breakers Circuit Breaker Pole Protection Vacuum Interrupter
- Epoxide Resin Insulating Media Dustproof Vacuum Circuit Breakers Circuit Breaker Pole
- GB / DL Standards Moistureproof Vacuum Circuit Breakers Circuit Breaker Pole
- Stable Insulating Ability Vacuum Circuit Breakers Circuit Breaker Pole
- Vacuum Circuit Breakers Interrupter Circuit Breaker Pole with Epoxide Resin Solid Material
- 3 phase 40.5kv 50 / 60Hz VMD5 Indoor Vacuum High Voltage Circuit Breaker
- ZN85 AC 50HZ 40.5kv / 36kv indoors three phase High Voltage Circuit Breaker
- ZN85 DC 110V, 220V 40.5kV, ac 50H indoors Vacuum High Voltage Circuit Breaker
- VMD5 series indoor 40.5 kv 50 / 60Hz Vacuum High Voltage Circuit Breaker apply in airport
- Indoor Vacuum High Voltage Circuit Breaker pass GB/T 11022 -1999, mechanical lift tests
- 24 kv VMD4 indoor three phase Vacuum Medium Voltage Circuit Breaker pass DL403
- Rated Current 630A 50 Hz 24kv VS1 Vacuum Medium Voltage Circuit Breaker for 12kv Switchger
Popular Searches
Recommended Products
- TS Dewatering Screen
- WRH-100B Middle Temperature Stainless Steel Fruit And Vegetable Dehydrator
- Tunnel type multi-layer dryer
- MDH-II Drying machine
- SCJ-B Fire hose dryer
- Magnesium Sulfate Heptahydrate Production Plant From Waste Sulfuric Acid
- Coal Briquette Molding(0086-15978436639)
- Mill Scale Briquettes Press(0086-15978436639)
- 1X10m Dust-Free Far Infrared Tunnel Dryer
- Hot Sale Factory Price Rotary Kiln Drum Dryer Cow Dung Dryer Clay Dryer
- spray freeze drying equipment/fruit freeze drying machine
- Small commercial lyophilizer vacuum freeze drying equipment machine Mini home use freeze dryer price
Find Similar Products By Category
- Machinery > Chemical & Pharmaceutical Machinery > Chemical Machinery & Equipment > Drying Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Alec Sun
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile