Home > Products > Automatic Barrier Gate > 6 Meter IP44 Automatic Barrier Gate Parking Lot Retractable Barrier Gates With Wire Control
6 Meter IP44 Automatic Barrier Gate Parking Lot Retractable Barrier Gates With Wire Control
- 0 Piece / Pieces per Month
- T/T L/C D/P D/A
- 7 days
- 6S / 3S Single Straight Boom Car Park Security Barriers With Fan Colling Machine
- Manual Vehicle Barrier Gate with RS485 Communication Module Straight Boom
- Intelligent Straight Residential Area Car Park Security Barriers Gate Arms
- RS485 Communication Module Both Traffic Barrier Gate of Left And Right Installed
- Highway Toll Collection Drop Arm Barrier , Automotive Access Control Parking Lot Barrier Gates
- Aluminum Alloy Straight Vehicle Barrier Gates Remote Control and Loop Sensor With Durable Motor
Product Details
Brand Name: | WONSUN | Place of Origin: | China | Model Number: | DZTP-133-A |
Product Description
Certification:CE, ISO, SGS
6 Meter IP44 Automatic Barrier Gate Parking Lot Retractable Barrier Gates With Wire Control
Model Selection and Differences
Specifications
Model |
WST1211 |
Working Temperature |
-40℃~+75℃ |
Voltage |
220V±10%, 110V±10%, 50/60HZ |
Rated power |
80W |
Relative humidity |
≤90% |
Remote control distance |
≥30m |
Net weight |
48kgs |
Speed |
1S,1.8S,3S, 6S |
Max boom length |
6 meters |
Motor Rotational speed |
1400rmp |
Protection Degree |
IP44 |
1 pcs Gate Barrier
1 pcs arm boom (from 1m to 6m can customised)
1 pcs control panel(built inside)
2 pcs remote controllers
1 pcs manual book
Communication with customers
Â
1)Â Â Â Â Â Q:Â Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
Â
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
Â
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
Â
3)Â Â Â Q:Â Motor running but traffic barrier gate arm no action?
Â
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
3 |
Low working voltage |
Check the voltage and power |
Â
4)  Q: When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
Â
A. |
Reason |
Solution |
1 |
Length adjustment of connecting rod not correct |
Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 |
Nuts on the limit switch loose |
Tighten the nuts when arm at 90° vertical and 180° horizontal |