- Chongqing Enrich Engineering and Technology Co., Ltd
- Main products: hydropower plant equipments, electric power equipments, power distribution equipments, hydro turbine generator, Industrial water filter&oil purifier, Instrument transformer, Power quality monitoring&improvement, Reactor/Inductor, Busduct, Circuit breaker&Isolating switch&Load switch, Filter press, Slurry Pump
Home > Products > Power quality treatment Reactive power compensation > Three Phase High Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg Compensator of Overall Efficiency More Than 97% Dynamic Static Reactive Power Compensation device static var compensation SVC Flexible AC Transmission Systemssvc Start
Three Phase High Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg Compensator of Overall Efficiency More Than 97% Dynamic Static Reactive Power Compensation device static var compensation SVC Flexible AC Transmission Systemssvc Start
- 5000 Set / Sets per Month
- Chongqing
- T/T
- 15 days
You May Like
-
Tbbw Intelligent Reactive Power Compensation Device for low-voltage lv power grids low-voltage power distribution systems to increase power factor reduce reactive power loss improve power supplyquality
-
Tbbx Low Voltage LV Metallized Polyester Film Capacitor Bank Reactive Power Local Compensation Device for low voltage power distribution system next to in parallel with the inductive load
-
TBB 6kv 600kVA 6kv 900kVA 10kv 4800kVA 10kv 3000kVA 35kv 10000kVA 35kv 6000kVA Complete Set of High-Voltage HV Reactive Power Capacitor Compensation Shunt Device Cabinet Equipment Frame Parallel
-
Tbbz Series High Voltage HV Group Automatic Switching Shunt Capacitor Reactive Power Automatic Compensation Device Cabinet 6kv, 10kv, 35kv transmission and distribution systems to optimizes power quality
-
Tbbwz Series Outdoor High-Voltage HV Pole Installation Type 6-10kV Power Transmission Distribution Line Shunt Power Capacitor Reactive Power Automatic Compensation Device to improve power factor reduce line loss improve voltage quality
-
Tbbx/J Series Indoor 6-10kV 50HZ Centralization High-Voltage HV Shunt Capacitor Reactive Power Local Compensation Device Cabinet with Capacitor Over-Pressure Protection Installations PF Correction with Capacitor for three-phase AC motor
Product Details
Brand Name | Enrich | Place of Origin | China | |
Model Number | EN SVG-400V-200kvar/4L, SVC |
Product Description
EN SVG Static var generator
Model description
EN SVG-400V-200kvar/4L
EN: Company code
SVG: Static var generator
400V: Voltage
200kvar: Capacity: 35kvar (35,50,75 and 100 kvar optional)
4L: Three phase four wire 3L: three phase three wire
EN SVG Static var generator can detect the loaded current in a real time through the external current transformer, extracting the reactive power contents of the loaded current calculated by the internal DSP, and then control the PWM signal generator to deliver signals to the internal IGBT, which makes the converter bring the reactive compensated current, meeting the requirement based on the setting values and finally realize the purpose of dynamic reactive compensation.
Three phase unbalance compensation
The switching times can be over 10000 times per second, with quick response and dynamic compensation.
Conditions of use
1.Environmental temperature: -10℃ ~ +40℃
2.Relative humidity: :5%~ 95% without condensation.
3.Altitude: ≤1500m, between 1500 ~4000m, according to GB/T3859.2, the power will be lowered by 1%
when adding 100m.
4.Environmental conditions: no harmful gas and steam, no conductive or explosive dust, no violent mechanical vibration
Technical parameters
1.Rated input line voltage: 400V(-20% ~ +20%)
2.Power grid frequency: 50Hz (range: 45Hz ~ 55Hz)
3.Power grid structure: three phase three wire, three phase four wire (400V)
4.Current transformer: 100/5 ~5,000/5
5.Circuit topology: Tri-level
6.Overall efficiency: ≥97%
7.Target power factor: 1
Performance
1.Single module capacity: 400V (35A, 50A, 75A and 100A optional)
2.Response time<10ms
3.Intelligent air cooling: with good ventilation condition
4.Noise:<70dB
Communication monitoring
1.Communication interface: RS485, CAN interface
2.Communication protocol: electrical total protocol, Modbus protocol
3.Protection function: Overvoltage protection, under-voltage protection, short circuit protection, over current protection, over temperature protection, driving fault protection, and double protection of lightning protection
4.Error alarming: support independent monitoring or concentrate monitoring.
Models
ENSVG-400V-35kvar / 3L
ENSVG-400V-50kvar / 3L
ENSVG-400V-75kvar /3L
ENSVG-400V-100kvar / 3L
ENSVG-400V-200kvar / 3L
ENSVG-400V-300kvar / 3L
ENSVG-400V-400kvar / 3L
ENSVG-400V-35kvar / 4L
ENSVG-400V-50kvar / 4L
ENSVG-400V-75kvar / 4L
ENSVG-400V-100kvar / 4L
ENSVG-400V-200kvar / 4L
ENSVG-400V-300kvar / 4L
ENSVG-400V-400kvar / 4L
Dynamic reactive power compensation device
(SVC- static var compensation)
EN SVC dynamic reactive power compensation device, the main circuit uses non-inrush current contactor or thyristor non-contact switch to switch the tuning capacitor bank (tuning reactance + capacitor bank). The control part is based on DSP technology, combining the theory of instantaneous reactive power with fast Fourier transform (FFT), highly-speed analyze voltage and current harmonic components in the system, real-time track and instantaneously compensate reactive power in the power grid, zero-crossing switching control technology of the tuning capacitor bank fully realize single-phase and three-phase tuning capacitor bank switching with no transient state and high-speed, so that the reactive power is dynamically compensated. Zero-crossing switching technology does not include transients and harmonics. It has the characteristics of no closing surge current, no arc reignition, no operating overvoltage, capacitors can be switched on again without discharging, fast tracking of reactive power changes, frequent switching, and fast dynamic response. Grouped multi-level compensation can be realized one time, and unbalanced load can be phase-compensated. Dynamic response time of dynamic reactive power compensation device: less than 20ms, power factor increased to above 0.92.
Application occasion
The dynamic reactive power compensation device is suitable for the occasions in the enterprise that need to compensate reactive power or need to filter out specific sub harmonic.
Features
1.Thyristor as non-contact switch, 1us ~ 3us switch
2.Zero voltage difference input and zero current removal technology
3.Dynamic reactive power compensation device switching without impact
4.Split phase compensation is all realized, which is close to stepless dynamic compensation
5.Harmonic suppression or control function
6.Complete protection
7.Friendly interface of dynamic reactive power compensation device
Technical parameters
Compensation capacity(kvar) | 90 | 150 | 240 | 500 |
Rated voltage | AC380V | |||
Power supply frequency | 50Hz | |||
Power supply phases | 3 phase 3 wire or 3 phase 4 wire | |||
Current sensor | Current Transformer | |||
Harmonic suppression times | 3 ~ 13th harmonic suppression | |||
Dynamic compensation response time | 1us~3us | |||
Protective function | Over-voltage, under-voltage, over-current | |||
Cooling method | Air-cooled | |||
Efficiency | Full load > 96% | |||
Operating ambient temperature | -30~+50℃ | |||
Relative humidity | <90%(25℃) |
Other low voltage compensation device:
Purposed reactive power compensation device for low-voltage arc furnace
Contact Us
- Chongqing Enrich Engineering and Technology Co., Ltd
- Contact nameGuangjian Duan Chat Now
- Phone86-23-62540401
Product Categories
New Products
-
High Quality High Voltage HV Three Phase Three Wire Static Var Generator Svg Compensator Module Steplessly Compensate Reactive Power Reactive Power Compensation Device for Electricity Saving Device Msvc
-
New Design Customized Industrial Broadcast Sheet Metal Fabrication Security Control Room Console Command Center Furniture Monitor Console Equipment Console Worktop Operating Platform Industrial Control Operating Desk with LED Lamp
-
Dcs Scada Mosaic Mimic Screen Power Simulation Screen for control room center
-
OEM Suctomized Kyn Rmu Hxgn Low Voltage LV Middle Voltage Medium Voltage MV High Voltage HV Control Panel Distribution Switchgear Cabinet Removable Fixed Type Sheet Metal Clad Frame Cabinet Electrical Electric Box Enclosure IP Sheet Metal Stamping Case
-
Tyd35 3-0.01 (0.02) H Type High Voltage HV Oil-Immersed Oil-Filled Capacitive Capacitance Capacitor Type Potential Voltage Transformer for Transformer PT
-
Jdqx6-66/110/220 Sf6 Sulfur hexafluoride Gas Insulation Insulated Potential Voltage Transformer PT 66kv, 110kv, 220kv
-
Jd6-35 Oil-Immersed Oil-Filled Type Potential Voltage Transformer PT 27.5kv, 35kv, 66kv, 72.5kv, 110kv, 126kv, 220kv, 245kv
-
Jlszv-20W Outdoor Three-Phase Three-Wire Casting Insulation Epoxy-Resin Combined Current and Potential Voltage Transformer CT/PT 20kv, 35kv with Fuse Protection
-
3kv, 6kv, 10kv Jdzx9-3, 6, 10q (B, C, D, E) Fully Enclosed Indoor Epoxy Cast-Resin Casting Insulation Type Single-Phase Potential Voltage Transformer PT with Fuse Protection Residual Voltage Winding
-
Lvqb-110 Series Sf6 Sulfur hexafluoride Gas Insulated Insulation Inverted Current Transformer Protect electrical Current Transformer CT 35kv, 66kv, 110kv, 220kv current sensor current transducer electric energy measurement, measuring, and relay protection
-
Lgbj-220 High Voltage HV Electromagnetic Organic Composite Insulation Dry Type electrical Current Transformer CT 35kv, 66kv, 110kv, 220kv power system current sensor current transducer Current Protector
-
Lb6-110 Lb7-220 Type Oil-Immersed Oil-Filled Hair-Pin Type Fully sealed Structure Current Transformer CT with Protection Class 35kv, 66kv, 110kv, 220kv, 330kv power system
-
Lvb-110 Lvb-220 Lvb1-220 Series Oil Immersed Oil-filled Inverted Type Current Transformers CT Instrument Transformer with Protection Class 35kv, 66kv, 110kv, 220kv
-
10kv 12kv 24kv 33kv to 550kv External or Built in Type Epoxy Resin Bushing Current Transformer for Power Transformer and Circuit Breaker with Stainless Cover Bushing Type Current Transformer Bushing Current Transformer CT for Switchgear Generator GIS
-
20kv Lmzb (T) 2 (3, 4, 5, 6, 8) -20 (G1, 3, 4, 5, 7, 8) /2 (3, 4) -180 (200) Epoxy Resin Casting Insulation Through-Wall Type Open Busbar Type Current Transformer CT with Transient Protection
-
20kv Lmzb (D) (T) 1 (2, 3, 7, 8) -20 (G1, 2, 3, 6) /2 (3, 4) Reinforced Increased Capacity Epoxy Resin Casting Insulation Through-Wall Type Enclosed Closed Busbar Busway Busduct Current Transformer CT with Protective Class with Transient Protection
-
10kv Laj-10q Lazbj-10 LFZBJ-10 Lm-6q Ldzj1-10 Lmzb6 -10 Ldz1-10 La-10q Lfzb9-10 Indoor Wall Through Through-Wall Type Epoxy Resin Cast-Resin Current Transformer CT
-
10kv 12kv 20kv 24kv 36kv LZZBJ9-10 Lzzbj9-10A3g Lzzbj9-24/180b/2 Dry Type Indoor Block Type Fully Enclosed Post Pillar Type Single Phase Epoxy Epoxide Resin Insulation Current Transformer CT 5/5A~500/5A OEM for Mv Switchgear
-
LJM-1, 2, 3 Bus-Type Indoor Busbar Type Zero Sequence Current Transformer CT Earthing Protection Residual CT for power system
-
Lxbk1 Lxbk2/3/4... Indoor Electromagnetic Type Toroidal Type Epoxy Resin Open-Close Split Core Core Balance Type Zero Sequence Current Transformer CT Residual Current Transformer CT with Protective Class Earthing Grounding Protection Suitable for Power Me
-
Lxk Indoor Electromagnetic Round Toroidal ring Type Epoxy Resin Open-Close Split Core Core Balance Type Zero Sequence Current Transformer CT Residual Current Transformer CT Earthing Grounding Protection Suitable for Power Measurement in Power Cable Syste
-
Lj-75, 80, 95 Series Indoor Electromagnetic Type Electric Power Cable Type TOROIDAL Ring Round type Zero Sequence Current Transformer CT Earthing Grounding Protection Residual Current Transformer for Power Measurement in Power System
-
LJZ-Φ65 Indoor Electromagnetic Electric Power Cable TOROIDAL Ring Round type Epoxy Resin Casting Insulation Insulated Zero Sequence Current Transformer CT Earthing Grounding Protection Residual Current Transformer CT for Power Measurement in Power Syste
-
LJ-1, 2, 4, 7 Indoor Electromagnetic Electric Power Cable Type TOROIDAL Ring Round type Zero Sequence Current Transformer CT Earthing Grounding Protection Residual Current Transformer CT for Power Measurement in Power System in Electrical Switchgear Contr
Popular Searches
Recommended Products
- EKI4 Current Cable Short Circuit And Grounding Fault Locator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Zinc Oxide Varistor metal oxide varistor MOV for surge arrester lightning arrester
- arrester
- HARSVERT-VA10/850 HARSVERT-VS10/850 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/830 HARSVERT-VS10/830 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/745 HARSVERT-VS10/745 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/680 HARSVERT-VS10/680 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/650 HARSVERT-VS10/650 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/605 HARSVERT-VS10/605 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/580 HARSVERT-VS10/580 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/550 HARSVERT-VS10/550 Medium Voltage Variable frequency drive 10kV VFD
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Guangjian Duan
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile