Home > Products > AC/DC Hipot Test > 40KV VLF Test Set Testing Power Cable with Extruded Insulation
40KV VLF Test Set Testing Power Cable with Extruded Insulation
- 100 Piece / Pieces per Month
- Shenzhen Shanghai. Guangdong
- T/T Credit Card
- 80KV VLF Test Set for Medium Voltage Power Cable with Extruded Insulation
- 80KV VLF Test Set for Low Voltage Power Cable with Extruded Insulation
- 40KV VLF Test Set for Medium Voltage Power Cable with Extruded Insulation
- 40KV VLF Test Set for Low Voltage Power Cable
- 40KV VLF Test Set for 6KV-10KV XLPE cables of acceptance tests at the jobsite
- 40KV VLF Test Set for 6KV-10KV PVC cables of preventive tests
Product Details
Brand Name: | Sansion | Place of Origin: | Hubei, China | Model Number: | SXVLF |
Product Description
General Information:
VLF Test Sets from 30kV - 90kV with Sine Wave Output
VLF means 'Very Low Frequency' is used in AC hipot test for power cables, transformers, switchgear and other electrical apparatus.
A VLF hipot is just an AC output tester but with an output frequency of 0.1 Hz or lower rather than 50/60Hz. Although the frequency is very low, it is still an alternating current with polarity reversals every half cycle. At 0.1 Hz output, rather than 60Hz, it takes 600 times less current and power to apply an AC voltage to a capacitive load, like a long cable.
Features:
√ Adapts microprocessor controlled, can realize voltage set-up/down, measuring and protecting automatically. Manual intervention is allowable even during the auto voltage boosting.
√ Portable, easy to move.
√ Large LCD can display waveform clearly, and test report can be printed by built-in printer.
√ The data of current, voltage, and waveform can be sampled at HV side.
√ Over voltage protection: When the output is beyond the limitation, the control unit will shut itself down within 20ms.
√ Over current protection: high & low voltage double protection, the precision value of power off protection can be setting at HV side. When the current of LV side is exceeded rated, the control unit will shut itself down within 20ms.
√ HV output protection resistor is built in the booster, not need to connect outside resistor.
√ Adapting high & low voltage closed loop negative feedback control circuit, there is no capacitive rise effect during the output.
Specifications:
√ Accuracy: 3%
√ Voltage +/- peak value error: ≤3%
√ Voltage waveform distortion: ≤5%
√ Working temperature: -10ºC+40ºC
√ Working humidity: ≤85%RH
Model |
Output Voltage/Current |
Load Capacity |
Fuse |
Control Unit |
Booster |
||
Net Dim. |
Net Wt |
Net Dim. |
Net Wt |
||||
SXVLF-30/1.1 |
30KV/29mA |
0.1Hz ≤ 1.1uF |
8A |
28×37×22 |
4 |
33×18×34 |
25 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-40/1.1 |
40KV/29mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
35×20×36 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-50/1.1 |
50KV/59mA |
0.1Hz ≤ 1.1uF |
|
28×37×22 |
4 |
37×24×39 |
45 |
0.05Hz ≤ 2.2uF |
|||||||
0.02Hz ≤ 5.5uF |
|||||||
SXVLF-60/0.5 |
60KV/59mA |
0.1Hz ≤ 0.5uF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz ≤ 1.0uF |
|||||||
0.02Hz ≤ 2.5uF |
|||||||
SXVLF-70/0.5 |
70KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-80/0.5 |
80KV/59mA |
0.1 Hz, ≤0.5µF |
20A |
28×37×22 |
4 |
33×18×34 |
25+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
|||||||
SXVLF-90/0.5 |
90KV/59mA |
0.1 Hz, ≤0.5µF |
|
28×37×22 |
4 |
33×20×35 |
30+45 |
0.05Hz, ≤1.0µF |
|||||||
0.02Hz, ≤2.5µF |
Contact Us
- Wuhan Sansion Power Equipment Manufacturing Co., Ltd.
- 40KV VLF Test Set for 6KV-10KV XLPE cables of preventive tests at the jobsite
- 40KV VLF Test Set for 6KV-10KV PVC cables of acceptance tests at the jobsite
- 50KV Fully Automatic AC Hipot Test Sets
- 100KV Fully Automatic AC Dielectric Test Set
- 10KVA/100KV Two Polarities DC Hipot System
- Fully Automatic AC Hipot Test Sets for Switchgears
- Fully Automatic AC Hipot Test Sets for Transformers
- Fully Automatic AC Hipot Test Sets for Motors
- Fully Automatic AC Dielectric Test Set for CT/PT
- Fully Automatic AC Dielectric Test Set for Isolators
- Fully Automatic AC Hipot Test Sets for The Withstand Voltage Test
- Fully Automatic AC Hipot Test Sets for Dielectric Withstand Voltage Test
- 800KV/80KJ Impulse Voltage Test System
- 800KV/80KJ Impulse Voltage Test System Generate Impulse Voltages 800KV Simulating Lighting Strokes
- 800KV/80KJ Impulse Voltage Test System Generate Impulse Voltages 800KV Simulating Switching Surges
- 800KV/80KJ Impulse Voltage Test System is Used for Carrying Out Impulse Voltage Tests on Power Transformers
- 800KV/80KJ Impulse Voltage Test System is Used for Carrying Out Impulse Voltage Tests on Instrument Transformers
- 800KV/80KJ Impulse Voltage Test System is Used for Carrying Out Impulse Voltage Tests on Switchgear
- 800KV/80KJ Impulse Voltage Test System is Used for Carrying Out Impulse Voltage Tests on HV Cable
- 1600KV/160KJ Impulse Voltage Test System
- 1600KV/160KJ Impulse Voltage Test System Generate Impulse Voltages 1600KV Simulating Lighting Strokes
- 60kv/2mA DC Hipot Tester for High Voltage DC Withstand Test
- 60kv/3mA DC Hipot Tester for HV DC Leakage Measurement
- 60kv/5mA DC Hipot Tester/High Voltage DC Withstand Test Sets
Popular Searches
Recommended Products
- Flash Fire Point Apparatus Fully Automatic Closed Cup Flash Point Tester
- Tessonics RSWA F-1: The Cost-Effective Choice for Spot Weld Inspection
- Coating thickness measuring instrumentDB22-CM221
- Hand-held torsion meter DB25-204TM-1N.m/5N.m/20N.m
- Ultrasonic Thickness Gauge DB22-TM240B
- Ultrasonic Thickness Gauge DB22-TM240A/B
- Vibration Meter DB10-VC260
- Testing Equipment Dissolution Apparatus Tablet Dissolution Tester
- fully automatic calorimeter hw-5000b
- fully automatic calorimeter ct-6000 type
- supply fully automatic calorimeter hw-5000a type
- Sandblasting and shot blasting roughness meter
Find Similar Products By Category
- Measurement & Analysis Instruments > Testing Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile