
- Zhuhai City Snova Technology Co., LTD
- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Short Circuit and Earth Fault Indicator > SNV-EFI Grounding Fault Indicator
SNV-EFI Grounding Fault Indicator
- 100000 Piece / Pieces per Month
- T/T
You May Like
-
Electrical equipment supplier cable short circuit and grounding fault indicator SNV-EKL3.2
-
Communication fault passage indication system for overhead 33KV and 11KV networks
-
SNV-EFI 3.0 Grounding fault indicator with LCD disply
-
Distribution automatiom grounding fault indicator
-
current and temperature online inspection fault sensor
-
Overhead Fault Indicator Fault localization device
Product Description
SNV-EFI Earth fault indicator
Type: surface mounted
Description
SNV-EFI earth fault indicator, it Widely used in various ring cabinets, high/ Medium or low -voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid in the Low/medium voltage network. The use of cable type grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction, and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.
Equipped with fault remote transmission port, suitable for distribution network automation; Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 10 years); external structure using card or lock design, the whole machine is easy to load and unload.
Function character:
1) Intelligent detection of ground fault and through the corresponding LED on the display unit to indicate fault.
2)Display unit designed with button, it is convenient for reset or test.
3)The pulse width time of fault current can be set to prevent incorrect fault indication caused by surge current.
4)It can reset and detect the remote fault indication device remotely by Scada or press key.
5)It can provide switch volume for external devices through remote contact.
6)It can choose the reset time after fault happen (when purchase, it need to tell factory to set,default 8hours).
7)Remote fault indicating can be made by external lamp.
8)Earth fault alarm current,Multi-level can be settable through a DIP inside of the display nit(optional)
9)Low battery display and alarm test through press the “Test/reset” key by 3seconds.
10) Battery can be changeable conveniently.
Function description
1) Earth fault alarm indicating: when the earth fault sensor detected an earth fault current, and the current is bigger than equal to or equal to the setting value, then the earth fault sensor send a signal to display unit through electric cable. And the display unit will display the alarm signal, at same time, the earth fault LED will be blinking.
2) Battery low voltage alarm indicating: the display unit use the battery to supply power. When we press the “Test” button,3seconds time: If the battery voltage is lower than the Min. working voltage 2.5V, then the Battery Level Led will be blinking 5 times; If battery voltage is normal, then only blink 1 times.
4)Automatic time reset: After the indicator alarm the fault, if there are without manual reset it, when the time reach our reset time setting, indicator will automatically reset.
5) Manual reset: After the indicator alarm the fault, user can press the button “ reset/test” in a short time to reset it.
6)Automatic Low voltage reset: Through inputting AC110-240V power to the pin 10,11 on the PCB in the display unit, when fault indicating, at same the voltage powered off. when the voltage recover and power on again, then indicator will be reset immediately via low voltage.
7) Out side AC110-240V power supply energy for display unit. It use the same as voltage of the “voltage reset” via pin 10,11.
8) Remote(Scada) reset/test: through short connect the pin 3,4, then indicator will be run the reset/test process, and Led will be blinking. *Connect the pin 3,4 by short time(1second), then it will be reset indicator. * connect the pin3,4 by a long time(3seconds), then it will be test indicator.
9)Remote indicating: Through connect the pin 5,6 to the external lamp , then it will be indicate fault when any phase alarm fault.
Technology paratmater
Voltage grade | AC110V-40.5KV | Battery life | ≥10 year | |||||
Frequency | 50HZ/60HZ | Low voltage alarm of battery | ≤2.5V | |||||
Earth fault alarm current(optional) | 10/25/50/75/100/125A/250 Default :50A | Earth fault sensor copper cable length | 5meter,or customized | |||||
Alarm current accuracy | ±10% | Load fluctuation and escape pulse time setting | Earth fault | 20/40ms,60ms,80ms,160ms (dip switch settable) | ||||
Rated frequency withstand voltage | 2KV/1min | |||||||
Relay contact capacity | ≤95W | work environment | Temperature | -40℃~+60℃ | ||||
Reset time | settable | 1-24H,or customized | Humidity | ≤95%RH | ||||
Working power | ER14505 battery | lithium battery (LiSOCl2) 3.6V/2700mAh | Use for cable diameter | Earth fault sensor (Cable, type E) | A | Ф60mm~110mm Normally | ||
Working current | Standby state | ≤10μA | B | Ф80mm~150mm Customized | ||||
Working state | ≤1mA | |||||||
Indicator protection level | Display unit | IP 65 | ||||||
Sensor CT | IP 67 |
Define and connect of terminal inside box.
Pin 1-2 : sensor connect
Pin 3-4 : Remote Reset/ test
Pin 5-6: External indicating LED
Pin 7-8: NC relay ,
Pin 7-9: NO relay
Pin 10-11: power supply and voltage reset (AC110-240V)
Operation description
1) Test: Before installation, press the display panel’s “ reset/test “ button, 3 second. Then the indicator will go into the self- checking state:
--Battery Level voltage led flash 1 times, (if the battery low voltage, it flash 5 times);
-- Fault indicating led flash, after 10 second, display unit will recover back the normal state. Or shortly press the “ reset/test” button to finish the self-checking state.
2) Clean Alarm: After fault indicating, when we solve the line or device problem, we can reset the indicator to Clean alarm as below three way:
1. shortly press the “ reset/test” button to clean alarm,
2. remote (scada) reset through connect Pin 3,4 by scada or key-switch control
3. wait it automatically reset after reset time setting value.
4. Voltage reset: when display unit voltage OFF , then voltage ON again.
Note: in order to use this Voltage reset feature, the 110-240Vac voltage must disappear when the fault occurs, i.e. it must be cut off by the MV circuit breaker that breaks the faulty line, otherwise the EFI will not operate voltage reset.
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
SNV-EFI earth fault indicator electric power sensor substation
-
Grounding Faul Indicator earth fault indicator
-
EFI Smart earth fault indicator for detecting grounding fault
-
Electric Handcart and Ground Knife Integrated Protector
-
SNV-EKL4 V2.1 Earth Fault Indicator for MV Power Distribution Network
-
New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
-
Overhead line fault passsage indicator working principle
-
Cable short circuit and grounding fault indicator SNV-EKL3.2
-
Underground indicators Earth fault indicator for smart grid SNV-EFI
-
Communication Grounding Fault Indicator RTU
-
Communication Grounding Fault Indicator RTU
-
Overhead Electric Line Fault Locator Device
-
New Design SNV-EKL4 v2.1 Earth fault and short circuit indicator
-
Grounding fault indicator SNV-EFI V1
-
How do Overhead Line Fault Indicator FPI Work?
-
Cable short circuit and grounding fault indicator SNV-EKL3.2
-
Overhead line fault passsage indicator working principle
-
New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
-
SNV-EFI earth fault indicator electric power sensor substation
-
SNOVA Technology Sell Intelligent Fault Circuit Indicator
-
10KV-138KV Overhead Line fault passage indicator with remote comunication
-
China factory supplier Power Accessories
-
Fault Indicator Remote Wireless Communication Terminal
-
Cable short circuit and grounding fault indicator SNV-EKL3.2
Popular Searches
- Monitoring System
- inductor
- ring main unit switchgear
- overhead cable
- cable line
- line fault indicator
- position indicator
- alarming apparatus
- electrical inductor
- short circuit indicator
- fault indicator sensor
- capacitive insulator
- short circuit fault indicator
- power indicator
- fault indicator
- cable fault indicator
Recommended Products
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSTD 110A 57160001-TZ Connection Unit new
- ABB DSTC170 57520001-BK communication interface unit
- ABB DSSR170 48990001-PC power supply unit
- ABB DSQC652 3HAC025917-001 I/O Unit brand new
- ABB DSQC643 3HACO24488-001 Panel Board New
- ABB DSQC611 3HAC13389-2 Contactor Unit new
- ABB DSQC609 3HAC14178-1 Power Supply Module
- ABB DSQC608 3HAC12934-1 Power Supply Module
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Accessories
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile