TRICONEX 3301
- 159 Piece / Pieces per Month
- T/T
- 1 days
Product Details
Brand Name: | TRICONEX | Place of Origin: | China | Model Number: | TRICONEX 3301 |
Product Description
Brand:TRICONEX
Type:3301
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
HI IDLE DELAY TIME—HOT (MINUTES) dflt= 1.0 (0.0, 500) Enter the hot start hold time desired at hi idle followed by ENTER. This is the programmable time, in minutes, that the turbine will wait/hold at the hi idle speed when a hot start is determined. If the turbine has been shutdown for longer than the Hot time but shorter than the Cold time, the control will interpolate between the Hot and Cold delays to determine the hi idle hold time. (Must be less than or equal to the ‘Hi Idle Delay—Cold’ Setting) RATE TO RATED SETPT—COLD (RPM/SEC) dflt= 5.0 (0.01, 500) Enter the cold start rate to the rated speed setpoint followed by ENTER. This is the programmable rate, in rpm per second, that the speed setpoint will accelerate at when moving to rated when a cold start is determined. RATE TO RATED SETPT—HOT (RPM/SEC) dflt= 5.0 (0.01, 500) Enter the hot start rate to the rated speed setpoint followed by ENTER. This is the programmable rate, in rpm per second, that the speed setpoint will accelerate at when moving to rated when a hot start is determined. If the turbine has been shutdown for longer than the Hot time but shorter than the Cold time, the control will interpolate between the Hot and Cold rates to determine the acceleration rate to the rated setpoint. (Must be greater than or equal to the ‘Rate to Rated—Cold’ Setting) RATED SETPT (RPM) dflt= 3600 (0.0, 20000) Enter the Rated Speed Setting followed by the ENTER key. This is the final speed setting when using the automatic start sequence. Once this speed setpoint is reached, the start sequence is complete. (Must be greater than or equal to the ‘Minimum Governor’ Setting) AUTO HALT AT IDLE SETPTS? dflt= NO (Yes/No) Select YES followed by the ENTER key to automatically halt the auto start sequence at the idle setpoints. This feature would result in the unit automatically stopping/halting at the low idle setpoint and at the high idle setpoint. Also, if the unit is started and the speed is above the low idle setpoint, the sequence will be halted. Select NO to allow the control to perform its automatic start sequence routine without interruption. EXTERNAL TRIPS IN TRIP RELAY ? dflt= YES (Yes/No) Select YES followed by the ENTER key to allow the external trip input(s) to de- energize the Trip Relay output. When set to NO, an external trip contact input to the 505 will shut down the 505 control but will not de-energize the 505’s trip relay output. RESET CLEARS TRIP OUTPUT ? dflt= NO (Yes/No) Select YES followed by the ENTER key to configure the Reset Clears Trip Relay output function. When set to YES, a Reset command will energize the trip relay output even when a trip condition is still sensed by the 505E— typically due to one of the external trip inputs. Once reset, the unit will be ‘Ready to Start’ as soon as all external trip inputs are closed. When NO, the trip relay output will be de-energized on a 505E trip and will not energize until all trips have cleared and a ‘Reset’ command is given. Speed Control Block When this header appears in the display, press the down arrow key to configure this block or press a left or right arrow key to select another block to configure. (The maximum turbine speed is 20000 rpm and the maximum speed input frequency is 15000 hertz.) TEETH SEEN BY MPU dflt= 60.0 (1.0, 300) Enter the number of teeth on gear that the speed probe is mounted on followed by the ENTER key.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
- HONEYWELL 51305072-300 CLCN-B
- HONEYWELL 51305896-200 NIM MODEM
- HONEYWELL 51306673-100 EPNI
- HONEYWELL 51401583-100 EPNI
- HONEYWELL 51402455-100 MP-DNCF02-200
- HONEYWELL 51402455-100 MP-DNCF02-201
- HONEYWELL 51403519-160 K4LCN-16
- HONEYWELL 51403645-100 SBHM
- LAM 810-800082-043
- S21260-SRS
- IS200SRTDH2ACB
- IS220PAICH2A 336A4940CSP11
Popular Searches
- lightning conductor
- Copper Lightning Rod
- Lightning Rod Clamp Earth Rod
- earthing system
- transmission rod
- 11 kv lightning arrester
- Copper Clad Steel Ground Rod
- static eliminator
- anti static device
- Air Blower Electrostatic Eliminator
- lightning connector
- plasma tv lift
- mtl safety barrier
- copper earthing bar
- copper earthing rods
- electrical earth rod
Recommended Products
- Beilai Allwinner T507-H processor with 8GB eMMC+ 1GB DDR4 and 2RS485 ARM Embeded Computer
- Wenglor Photoelectric Switch Sensor Wenglor IR020BE IB040NK74XB
- Allen-Bradley Photoelectric Switch Sensor AB 42CAEZ-U1MNB1 AB 42
- Allen-Bradley Inductive Sensor Inductive Proximity Switch AB 802RP
- Schneider MC-SSSA-025 Resolver Cable
- Schneider AS-W978-025 Cable
- Schneider AS-MEEP-001 Computer Accessory
- Schneider AS-BSIM-203 PLC Module/Rack
- Schneider AS-B824-016 Output Module
- Schneider AS-B804-116 Output Module
- Schneider 520VPU19200 handheld programmer
- Schneider 140XCP40200 Slot Blackplate
Find Similar Products By Category
- Electrical Equipment & Supplies > Other Electrical Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile