- Acrel Electric Co., Ltd
- Main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > AHKC Series Hall Sensor > Acrel AHKC-KDA current type hall sensor rated input AC 0-(400-2000)A output 4-20mA
Acrel AHKC-KDA current type hall sensor rated input AC 0-(400-2000)A output 4-20mA
- 1000 Piece / Pieces per Month
- T/T
- Acrel AHKC-H hall effect current sensorsrated input 0-(500-3000)A output 5V/4V
- Acrel AHKC-HB Hall Current Sensor rated input 0-(25000-40000)A output 5V/4V
- Acrel AHKC-HB hall effect sensor rated input 0-(10000-20000)A output 5V/4V
- Acrel AHKC-HB high accuracy hall sensor rated input 0-(2000-8000)A output 5V/4V
- Acrel AHKC-HBAA open loop hall sensor rated input DC0-(2000-8000)A output 4-20mA
- Acrel AHKC-EA split core closed-loop hall current sensor rated input 0-(200-1000)A output 5V/4V
Product Description
Hall current sensors are mainly used to isolate and convert Ac,DC,pulse and other complex signals .After signals are convertedaccording to the Hall Effect Theory,the can be directly acquired by AD,DSP,PLC, secondary instruments and other devices.Hall current sensors are widel applicable for acquisition and feedback control of current signals in the current monitoring,battery application,inverter,solar power management,direct current cabinet ,DC motor drive,electroplating,welding,frequency converter,UPS servo control systems.They feature the quick response ,wide range of measurement,high precision ,strong overload capcity,good linearity and excellent and anti-interference performace.
Parameters | Index |
Rated Input Current | AC0-(400-2000)A |
Rated Output Voltage | 4-20mA |
Accuracy Class | 1.0 |
Power Voltage | 12V/24V(allowable fluctuation±20%) |
Zero Offset Voltage | ±20mV |
Offset Voltage Drift | ≤±1.0mV/℃ |
Linearity | ≤0.2%FS |
Response Time | ≤5us |
Bandwidth | 0~20kHz |
Isolation Voltage | 3.5kV/50Hz/1min |
Operating Temperature | -40℃~85℃ |
Storage Temperature | -40℃~85℃ |
Consumption | ≤0.5W |
+15V—— power supply+15V
-15V ——power supply-15V (Note that power positive and negative poles cannot be inversely connected.)
M —— signal output end positive pole
G —— power ground and signal output end negative pole
Note: The specific wiring is subject to the terminal no. of object shell. 5. Precautions
1. When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and
assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram
the thread hole of Hall sensor module completely is proposed to use. 2. When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When
the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the
best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot
be more than 80℃. 3. When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of
calibration value. 4. The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use. 5. Zero and full scale regulator potentiometer can not be adjusted. 6. Auxiliary power supply is required to be deployed voluntarily. 7. Power positive and negative poles cannot be inversely connected. 6. Order Sample
Sample 1 AHKC-KA Hall current sensor
Auxiliary power supply:DC±15V
Input:800A
Output:5V
Accuracy:Grade 1
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
- Acrel AHKC-F hall effect sensor rated input 0-(200-1000)A output 5V/4V
- Acrel AHKC-H hall effect current sensors rated input 0-(500-3000)A output 5V/4V
- IDC AMC16-DETT DC Multi-Channel Energy Meter Din Rail With RS485 Connect Hall Sensors For Tower Base Station Mutiloop Instrument
- AMC16-DETT Multi-Circuits DC Energy Meter Class 1 Rated Voltage 1 Channel -48VDC RS485 Communication For Base Station
- DC Smart Kwh Energy Monitoring -48VDC with 1 Channel RS485 Port for Mobile Towers DC Multi Circuits Energy Meter
- Acrel AMC16-DETT Multi-loop DC Energy Power Meter -48VDC 1 Channel RS485 For Base Station Mobile Towers
- Acrel AMC16-DETT DC Smart KWH Energy Monitoring Meter -48VDC With 1 Channel RS485 Port for Mobile Towers
- AMC16Z-FAK High Accuracy Max 16 Circuits 3-Phase Multi-Channel Din Rail Ac Power Meter 220~264vac L-N Kwh AC Multifunction
- AMC16Z-FAK48 Multi-circuit AC Data Center Energy Meter High Accuracy Energy Meter Monitor 220~264Vac L-N Multi Circuit Power
- AMC16Z-FAK48 Multi-circuit AC Data Center Energy Meter AC Outgoing Branch Circuits Multi-metering 1phase 3 phase For Data Center
- Three Phase Energy Monitoring Device AMC16Z-FAK48 for Data Center System AC Outgoing Branch Circuits Multi-metering With RS485
- Din Rail Ac Power Meter AMC16Z-FAK48 Multi-circuit Energy Meter One RS485 Communication 48 Branch Full Electric Parameter
- Acrel Factory Selling Smart Automatic AM2SE RS485 Communication Overvoltage Overcurrent Protection Relay
- High Quality Smart Automatic AM2SE RS485 Communication Thermal Overload Switch Transformer Protection Relay
- AM2SE Thermal Switch Transformer Overload Protective Relay Earth Fault Negative Sequence Under Frequency
- AM2SE Over Current Protection Over Voltage Protection Relay For Factories Substations
- Acrel Low/Medium Voltage Net-loop Switchgear Protection Relay For Substations Transportation Industry
- ALP300 Motor overload Protection Devices 2 Programmable DI 4 Programmable DO Modbus-RTU Communication For Industrial Cement
- Acrel Motor Overload Protection Devices ALP300 For Cement Chemical Plant Pump Station Motor Protector With RS485
- Motor Protection Controller Device 2 Programmable DI 4 Programmable DO Modbus-RTU DC4-20mA Analog Output For Rail Transit
- Motor Overload Protection Devices ALP300 220V/240V Output Modbus-RTU Communication For Industrial Low Voltage Motor Controller
- High precision Acrel Three phase current analog Class 0.5 4-20ma current transmitter with RS485 Modbus-RTU optional
- BD-3I3 series Three phase current sensor transducer transmitter 3-phase 3-wire power transducer 4-20ma output
- Acrel BD-3I3 Three Phase Current CE Certified Transducer Sensor and Electrical Transducer with RS485 Modbus-RTU Optional
Popular Searches
Recommended Products
- High quality pepperls&fuchs OBR7500-R100-2EP-IO-V31 retroreflective sensor unit for IO-Link
- Pepperl+fuchs NCB5-18GM40-Z0
- 1PC New Pepperl+Fuchs UC6000-30GM-E6R2-V15 Inductiver Sensor Expedited Shipping
- New and Original Sensor for -PEPPERL FUCHS- NBB20-L2-A2-V1
- Original pepperl+fuchs 3RG Sensors Switches Ultrasonic Sensor 3RG6243-3PB00-PF
- Pepperl+fuchs NBB20-U1-UU
- Renishaw Original New A-5003-0050 M3 1.5 mm Ruby Ball Stylus - Tungsten Carbide Stem (L 20 mm EWL 12.5mm)
- Reading head T1031-10A RENISHAW Subdivision box grating ruler
- RENISHAW A-5000-3709 standard probe styli/CMM stylus Measuring Head OMP40 OMP60
- New & Original Renishaw RESA30USA350B RESOLUTE absolute encoder system with RESA30 rotary (angle) ring
- Renishaw A-5439-0050 OMI-2T
- New & Original Renishaw RESA30USA075B RESOLUTE absolute encoder system with RESA30 rotary (angle) ring
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile