
- Zhuhai City Snova Technology Co., LTD
- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Overhead Line Fault Indicator > Flicker type Overhead type Short circuit &Ground Fault Indicator
Flicker type Overhead type Short circuit &Ground Fault Indicator
- 500 Set / Sets per Month
- Shenzhen
- D/P D/A Other
- 7 days
You May Like
-
Smart Computer System for overheand line fault sensor
-
Electric Power Overhead type Cable Fault Indicator
-
EKI4 Current Cable Short Circuit And Grounding Fault Locator
-
How do overhead line fault indicator work
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Smart Computer System for overheand line fault sensor
Product Details
Brand Name | SNOVA | Place of Origin | China | |
Model Number | Overhead Line Earth And Short-circuit Fault Indicator |
Product Description
Overhead type Short circuit &Ground Fault Indicator
If you are interested in our products ,please contact with us .
Contacts:Andrew Mao
Email:snovatech@163.com or 626387134@qq.com
Mobile:0086-13570657698
WeChat :13570657698 QQ:626387134
The signals description of indicator
The fault indicator type flicker SNV308.2 has an ultra-bright, 360°red LED and a green LED pointing to the bottom for fault indication. Additionally it ha a yellow LED pointing to the bottom to signal its operational status.
1) Red LED: when permanent fault happen , the red LED will flash, 1 flash very 1 second.
2) Green LED: when Fault is temporary fault happen. The red LED will flash, at same time, additional green h every 1 second. ( Temporary fault character : when fault happen, and power off, but re-closer close successful, and power on again).
3) Yellow LED:
Yellow LED signals the operating state of the fault indicator. Operating states are:
__yellow LED does not blink, means fault indicator is on service state
__yellow LED blinks every second, means fault indicator is in radio mode
__yellow LED blinks every 3rd second, meanings the battery is running low.
Operational settings and functions of the SNV308.2
The operational settings of the fault indicator can be adjusted and read out with the remote control , Flicker type SNV306.2. Detailed information about all functions of the indicator basic settings like trip current and advanced settings like the auto re closer settings can be found in the instruction manual for the remote control, Flicker type SNV306.2. Information how to change or read out the settings can be also found there.
Please note: The online current can be read out with the remote control, Flicker type SNV306.2 |
Careful handling
When moving the adapter down to the ground, please move it downwards vertically. When placing it onto the ground horizontally the connection to the hot stick might break.
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
Smart Computer System for overheand line fault sensor
-
Computer Software for Power distribution Network
-
SNV-EFI Earth fault indicator grounding fault detection
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Remote Computer System for distribution system
-
Overhead line fault indicator
-
medium voltage overhead line fault current sensor and indicator
-
Intelligent Multifunctional Remote Control PDA
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
medium voltage overhead line fault current sensor and indicator
-
Overhead line fault indicator
-
SNV500 Series Intelligent dividing control system of Vacuum circuit breaker
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
SNV500 Series Intelligent dividing control system of Vacuum circuit breaker
-
Intelligent Multifunctional Remote Control PDA
-
How does a fault indicator work
-
GSM and GPRS/GPS remote Communication Terminal system,IEC101
-
Chinese Overhead type Short circuit & earth Fault Locator
-
Communication Terminal system
-
Electric Power Overhead Line Current Fault Indicator for smart-grids
-
SNV-EKL4 Earth Fault and Short Circuit Indicator
-
Remote Wireless Communication Terminal with fault sensor
-
communication terminal of overhead line fault indicator
-
Intelligent fault indicator with SCADAS
Popular Searches
- cable accessories
- Monitoring System
- control panel
- overhead
- ring main unit switchgear
- overhead cable
- cable fittings
- compact substation
- dc distribution box
- line fault indicator
- gis
- recessed box
- alarming apparatus
- electrical inductor
- short circuit indicator
- earth fault indicator
- fault indicator
- cable accessories
- Monitoring System
- fiber laser source
- inductor
- overhead
- overhead cable
- cable fittings
- tools kit
- fault detector
- line fault indicator
- position indicator
- alarming apparatus
- electrical inductor
Recommended Products
- Radar and Infrared Motion Active Siren Alarm Outdoor for High Electric Hazards Security Sites
- EKI4 Current Cable Short Circuit And Grounding Fault Locator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Zinc Oxide Varistor metal oxide varistor MOV for surge arrester lightning arrester
- arrester
- HARSVERT-VA10/850 HARSVERT-VS10/850 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/830 HARSVERT-VS10/830 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/745 HARSVERT-VS10/745 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/680 HARSVERT-VS10/680 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/650 HARSVERT-VS10/650 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/605 HARSVERT-VS10/605 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/580 HARSVERT-VS10/580 Medium Voltage Variable frequency drive 10kV VFD
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile