
- Zhuhai City Snova Technology Co., LTD
- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Overhead Line Fault Indicator > Flag type Overhead type Short circuit &Ground Fault Indicator
Flag type Overhead type Short circuit &Ground Fault Indicator
- 5000 Set / Sets per Month
- Shenzhen
- T/T D/P D/A Other
- 7 days
You May Like
-
Chinese factory Overhead Line cable Fault Locator
-
overhead Line fault indicator for installation methods and tools
-
short circuit and earth fault passage indicator with good price
-
overhead line fault sensor and control communication system
-
overhead line fault sensor and control communication system
-
Installation adapter of Overhead Line Fault Indicator
Product Details
Brand Name | SNOVA | Place of Origin | China | |
Model Number | SNV-308.1 |
Product Description
Fault indicator sensor Type:SNV308 Indicator
Description
SNV Indicators suitable for overhead lines with a 50KV below four remotes short circuit &Earth fault indicator, through measuring the current of a cable, to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and other information is uploaded to the remote server, which provides reliable data for the various types of fault diagnosis and location of overhead lines
Character:
l real-time sampling of current per cycle;
l ultra low power real-time sampling;
l When line current value≧5A,CT can supply meet the indicator power requirement
l Sampling accuracy5-20A±1.5A,20-800A±3%
l Sensor factory automatic calibration, to ensure consistency;
l intelligent motor control flop;
l Support remote, telemetry, remote control, remote adjust;
Function character
a. real time measurement of three-phase on line current;
b. Detection and judgment of short circuit fault;
a) support the determination of the set threshold, fault current, short circuit fault;
b) supports the determination of a set of mutated incremental currents for short-circuit faults;
c) supports the determination of the percentage of short circuit faults that can be set by the percentage of mutated currents;
d) support for reclosing identification;
c. Detection and judgment of ground fault;
d. Data Upload function;
a) periodically upload real-time online current, zero sequence current, and battery voltage;
b) Upload the fault status, the fault elimination status and the fault current value in real time;
e. Parameter setting
a) Available to change the parameter setting through Web server.
b) Available to change and set the parameter though remote setting control PDA;
c) Support RS232 port for parameter modification and maintenance;
f. Support setting controller (PDA)
a) Available reading and change setting parameter;
b) PDA can read Indicator sensor state , Real time line current, battery voltage data.
c) PDA can simulate the online fault test through setting Indicator’s parameter.
g. Intelligent motor control flop to red flag;
h. Six three-color fault indicating led;(red, green, blue)
i. One yellow state led light;
j. Support line CT power charge for battery;
k. Support timing reset, power on auto reset, remote reset;
l. can be efficiently mounted and unloaded;
m. The structure parts are made of antirust and anticorrosion material;
n. In waking up state(wireless setting model),During 7 minutes, without operate, there will be auto reset.(Tips: in waking up state, FI prohibited fault test)
Function display
Flag state
1) Normally, Flag is on blanket position. Every 3hour, Flag will reset one times for avoiding un fault turn to red flag.
2) When short circuit fault happen, it will turn to red flag state; After reach reset time or when the line current restore, Fault indicator will turn back to blanket state;
3) when the earth fault happen, it will turn to red flag state. It will be automatically turn back blanket state when line power off and current restore, or wait until reach reset time.
Fault indicating Led light:
1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2 second,And turn to red flag at same time。
2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2 second,And turn to red flag at same time。
3) Earth Fault indicating:Six 3-color led will shine Blue color, and four times, every 2 second. And turn to red flag at same time.
yellow state Led light:
Battery voltage too low:Shine 1 time, every2second
Battery voltage low: shine 2 time, evey2second
Wireless setting state: shine 4 times, every 2 second
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Simulated Failure Remote Controller for Overhead Line Fault Indicator
-
Electric Power Overhead type Cable Fault Indicator
-
how to reset overhead line earth fault indicator
-
Current Temperature And Faults On-line Monitoring instrument
-
Overhead type Fault Indicator and Wireless communication module
-
short circuit and earth fault indicator distribution system
-
Overhead Cable Fault Warning Device
-
Overhead power line fault indicator with Three color light display
-
15-55KV Overhead type Short circuit &Ground Fault locator
-
Electric Power Overhead Line Current Fault Indicator
-
communication terminal of overhead line fault indicator
-
earth fault indicator distribution system
-
Overhead Line cable Fault Locator
-
Overhead Line High Voltage Line fault locator Device
-
communication terminal of overhead line fault indicator
-
Индикатор замыкания на землю и короткого замыкания
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Индикатор замыкания на землю и короткого замыкания
-
Индикатор замыкания на землю и короткого замыкания
-
Индикатор замыкания на землю и короткого замыкания
-
EKI4 Current Cable Short Circuit And Grounding Fault Locator
-
Triphase Electric Power Monitor
-
Flag type Overhead type Short circuit &Ground Fault Indicator
Popular Searches
- switchgear
- distribution board
- Zinc Oxide Varistor
- Lightning Rod
- spd
- surge protector
- surge arrester
- surge suppressor
- power surge
- lightning arrester
- zinc oxide lightning arresters
- Lightning Arrester Rod
- Polymer Surge Arrester
- electrical switchgear
- zinc oxide varistors
- power distribution unit
- pdu
- Power Supply Device
- distribution cabinet
- Metal Oxide Varistor
- cabinet pdu
- rack pdu
- power distribution cabinet
- Power Resistor
- High Voltage Resistor
- switchboard
- hv switchgear
- gas insulated switchgear
- ring main unit
- voltage protector
Recommended Products
- Radar and Infrared Motion Active Siren Alarm Outdoor for High Electric Hazards Security Sites
- EKI4 Current Cable Short Circuit And Grounding Fault Locator
- Flag type Overhead type Short circuit &Ground Fault Indicator
- Zinc Oxide Varistor metal oxide varistor MOV for surge arrester lightning arrester
- arrester
- HARSVERT-VA10/850 HARSVERT-VS10/850 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/830 HARSVERT-VS10/830 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/745 HARSVERT-VS10/745 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/680 HARSVERT-VS10/680 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/650 HARSVERT-VS10/650 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/605 HARSVERT-VS10/605 Medium Voltage Variable frequency drive 10kV VFD
- HARSVERT-VA10/580 HARSVERT-VS10/580 Medium Voltage Variable frequency drive 10kV VFD
Find Similar Products By Category
- Electrical Equipment & Supplies > Power Distribution Equipment
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile