- Acrel Electric Co., Ltd
- Main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > AHKC Series Hall Sensor > Acrel AHKC-HB rated input 0-(2000-8000)A output 5V/4V high accuracy hall sensor
Acrel AHKC-HB rated input 0-(2000-8000)A output 5V/4V high accuracy hall sensor
- 1000 Piece / Pieces per Month
- T/T
- Acrel hall effect current sensors rated input AC0-(200-1000)A output 4-20mA AHKC-EKBDA
- Acrel rated input DC 0-(200-1000)A output 4-20mA AHKC-EKBA Open Loop DC Current Transducer
- Acrel AHKC-EKDA rated input AC0-(50-500)A output 4-20mA current type hall sensor
- Acrel AHKC-HBAA rated input DC0-(2000-8000)A output 4-20mA open loop hall sensor
- Acrel smart circuit breaker 4PASCB1-63-C16-4P With local manual push rod, local electric control, remote control, etc
- Acrel smart gateway can view the alarm, protection, fault and other status of each smart circuit breaker ASCB1-M-4G
Product Description
Hall current sensors are mainly used to isolate and convert Ac,DC,pulse and other complex signals .After signals are convertedaccording to the Hall Effect Theory,the can be directly acquired by AD,DSP,PLC, secondary instruments and other devices.Hall current sensors are widel applicable for acquisition and feedback control of current signals in the current monitoring,battery application,inverter,solar power management,direct current cabinet ,DC motor drive,electroplating,welding,frequency converter,UPS servo control systems.They feature the quick response ,wide range of measurement,high precision ,strong overload capcity,good linearity and excellent and anti-interference performace.
Parameters | Index |
Rated Input Current | 0-(2000-8000)A |
Rated Output Voltage | 5V/4V |
Accuracy Class | 1.0 |
Power Voltage | ±15V(allowable fluctuation±20%) |
Zero Offset Voltage | ±20mV |
Offset Voltage Drift | ≤±1.0mV/℃ |
Linearity | ≤0.2%FS |
Response Time | ≤5us |
Bandwidth | 0~20kHz |
Isolation Voltage | 3.5kV/50Hz/1min |
Operating Temperature | -40℃~85℃ |
Storage Temperature | -40℃~85℃ |
Consumption | ≤0.5W |
+15V—— power supply+15V
-15V ——power supply-15V (Note that power positive and negative poles cannot be inversely connected.)
M —— signal output end positive pole
G —— power ground and signal output end negative pole
Note: The specific wiring is subject to the terminal no. of object shell. 5. Precautions
1. When the Hall sensor is used, attention must be paid to the coupling between the primary side coil and
assistant side coil in order to get better dynamic characteristics and sensitivity, single conductor that should cram
the thread hole of Hall sensor module completely is proposed to use. 2. When the Hall sensor is used, the best measuring accuracy can be got under rated input current value. When
the measured current is much less than the rated value, the primary side can use multi-turns if want to obtain the
best accuracy, that is IpNp=rated ampere-turns. In addition, the temperature of the primary side feeder line cannot
be more than 80℃. 3. When the Hall current sensor is working normally, the auxiliary power supply cannot be more than ±20% of
calibration value. 4. The Hall Current sensor is strictly prohibited to be fallen from high place (≥1m) during installation and use. 5. Zero and full scale regulator potentiometer can not be adjusted. 6. Auxiliary power supply is required to be deployed voluntarily. 7. Power positive and negative poles cannot be inversely connected. 6. Order Sample
Sample 1 AHKC-KA Hall current sensor
Auxiliary power supply:DC±15V
Input:800A
Output:5V
Accuracy:Grade 1
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
- Acrel ASCB1-M-CE LCD displaysupports event recording Parameter setting and control of each intelligent control smart gateway
- Acrel Intelligent leakage circuit breaker monitorcurrent voltage power leakage andother parameters in real time ASCB1LE-63-C63-4P
- Acrel has timing control, remote control, local locking and other functions ASCB1LE-63-C32-4P smart leakage circuit breaker
- Acrel smart leakage circuit breaker 2P ASCB1LE-63-C16-2P Guide rail installation, local electric control, remote control, etc.
- Acrel smart leakage circuit breaker 2P ASCB1LE-63-C63-2P Can monitor voltage, current, leakage and other parameters in real time
- Acrel 2P ASCB1LE-63-C32-2P With short circuit over-temperature leakage and other protection functions intelligent leakage circuit breaker
- Acrel timing control, remote control, local locking and other functions. 4P smart leakage circuit breaker ASCB1LE-63-C16-4P
- Acrel ndustrial Isolated Monitoring Device AIM-T500 for unearthed system AC 690V DC 800V Real-time measurement of leakage
- Acrel electrical transducer power supply DC24V/12V low power consump BA50-AI/I in AC0-600A out 4-20mA/0-20mA
- Acrel electrical sensor BA50-AI/V in AC0-600A out 4-20mA/0-20mA power supply DC24V/12V low power consump
- Acrel power supply DC24V/12V low power consump BA20-AI/I in AC0-200A out 4-20mA/0-20mA electrical sensor
- Acrel power supply DC24V/12V Strong overload capability, low power electrical current transducer BA20-AI/V input AC0-200A
- Acrel in AC0-50A out 4-20mA BA10-AI/I electrical transducer power supply DC24V/12V Strong overload capability, low power consum
- Acrel electrical transducer BA10-AI/V in AC0-50A out 1-5V/0-5VA power supply DC24V/12V low power consumption
- Acrel BA50L(II)-AI/V Can be widely used in industrial automation fields out 1-5V/0-5V smart AC electrical current sensor
- Acrel BA50L(II)-AI/V smart AC electrical current sensor Can be widely used in industrial automation fields out 1-5V/0-5V
- Acrel smart AC electrical transducer BA50(II)-AI/V Mainly detects the leakage current of the electrical system
- Acrel Can be widely used in industrial automation fields smart AC current transformer BA20(II)-AI/V
- Acrel protector Digital tube display ALP300-5 Strong anti-interference ability, stable and reliable work, digital
- Acrel Strong anti-interference ability, stable and reliable work, digitaL Digital tube display Smart protector ALP300-25/C
- Acrel intelligent protector ALP300-50/C Start-up timeout, overload, underload, and equalization protection Digital tube display
- Acrel Digital tube display protectorStrong anti-interference ability, stable and reliable work, digital,Intelligent ALP300-100/C
- Acrel intelligent protector ALP300-250/C Strong anti-interference ability, stable and reliable work, digitaL Digital tube display
- Acrel AKH-0.66/L L-45 residual current transformer rated current 16-100A Applied to residual current signal collection
Popular Searches
Recommended Products
- High quality pepperls&fuchs OBR7500-R100-2EP-IO-V31 retroreflective sensor unit for IO-Link
- Pepperl+fuchs NCB5-18GM40-Z0
- 1PC New Pepperl+Fuchs UC6000-30GM-E6R2-V15 Inductiver Sensor Expedited Shipping
- New and Original Sensor for -PEPPERL FUCHS- NBB20-L2-A2-V1
- Original pepperl+fuchs 3RG Sensors Switches Ultrasonic Sensor 3RG6243-3PB00-PF
- Pepperl+fuchs NBB20-U1-UU
- Renishaw Original New A-5003-0050 M3 1.5 mm Ruby Ball Stylus - Tungsten Carbide Stem (L 20 mm EWL 12.5mm)
- Reading head T1031-10A RENISHAW Subdivision box grating ruler
- RENISHAW A-5000-3709 standard probe styli/CMM stylus Measuring Head OMP40 OMP60
- New & Original Renishaw RESA30USA350B RESOLUTE absolute encoder system with RESA30 rotary (angle) ring
- Renishaw A-5439-0050 OMI-2T
- New & Original Renishaw RESA30USA075B RESOLUTE absolute encoder system with RESA30 rotary (angle) ring
Find Similar Products By Category
- Electronic Components & Supplies > Active Components > Sensors
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile