- Acrel Electric Co., Ltd
- Main products:Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement
Home > Products > AGF-AE Series PV/Solar Invertor Energy Meter > Acrel DC Solar string monitoring device AGF-M4T Applied to intelligent photovoltaic bus box Accuracy 0.5 class
Acrel DC Solar string monitoring device AGF-M4T Applied to intelligent photovoltaic bus box Accuracy 0.5 class
- 100 Piece / Pieces per Month
- T/T L/C
- Acrel for low voltage protection with different levels of accuracy AKH-0.66/P P-60III Current transformer
- Acrel AKH-0.66/P P-100III Protective Current sensor for low voltage protection with different levels of accuracy
- Acrel Widely used in low voltage distribution protection system Protective current sensor AKH-0.66/P P-80II
- Protective current transformerAKH-0.66/P P-60II Widely used in low voltage distribution protection system
- Acrel AKH-0.66/P P-50II protective Current transformer for low voltage protection with different levels of accuracy
- Acrel AKH-0.66/P P-100*50II for low voltage Current transformer protection with different levels of accuracy
Product Description
General
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus)
communication port for transmitting all the datas to master device.
Product function
Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively
With 3-channel switching state monitoring to collect output idle contact information of DC breaker ,lightning protector. protector etc
Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format
English LCD display ,convenient to set parameters and check the data
Technical Parameters
Item | AGF-M4T | AGF-M8T | AGF-M12T | AGF-M16T | AGF-M20T | AGF-M24T |
Input channels | 4 | 8 | 12 | 16 | 20 | 24 |
Rated current | DC 0~20A | |||||
Response time | 1s | |||||
Accuracy | 0.5 class | |||||
Temperature coefficient | 400ppm | |||||
RS485 communication | RS485/ModBus-RTU protocol,4800/9600/19200/38400bps |
Additional function
Switch input | 3-way input(optocoupler or dry contact mode) |
General technical parameters | |
Temperature/ Humidity | Working temperature: -35~+65℃, humidity95%,no condensation, no corrosiongas place; *Display module work temperature:-20~+70℃ |
Temperature measurement function | To measure the inner temperature of box (-20℃~100℃) |
Altitude | ≤3000m |
Insulation resistance | ≥100MΩ |
Industrial frequency withstand voltage | power/communication/switching input/cell voltage input-- AC 2kV/1min(When the auxiliary power supply is DC1500V, the withstand voltage between the power supply, photocell input and other circuit is AC 2.7kV)Current input/power,cell voltage , communication,switching state—AC3.5kV/1min |
EMC | GB_T 17626.2-2006;Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact discharge 6kV. |
GB_T 17626.4-2008;Electrical fast transient immunity test grade 4, common mode 4kV, difference mode 2kV | |
GB_T 17626.5-2008;Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV | |
GB_T 17626.8-2006;Power frequency magnetic field immunity test grade 4 |
Solar PV Power Distribution Monitoring Solution
Practical Application of AGF-MxxT in PV Combiner Box
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
- Acrel protective Current Sensor AKH-0.66/P P-80III Current transformer for low voltage protection with different levels of accuracy
- Acrel AKH-0.66/P P-80*50II Widely used in low voltage distribution protection system Protective current sensor
- Acrel AKH-0.66/P P-60*50II Protective current sensor Widely used in low voltage distribution protection sys
- Protective current transformer AKH-0.66/P P-40II Widely used in low voltage distribution protection system
- Acrel ACR10R-D10TE LCD display for PV/Solar din rail RS485 single phase multifunction power meter
- Acrel PV/Solar inverter energy meter LCD display RS485 communication single phase ACR10R-D16TE
- Acrel ACR10R-D24TE single phase intelligent solar inverter energy meter power monitor with RS485 connection
- Acrel Din Rail Energy Meter ACR10R-D36TE Solar Din Rail Energy Meter Single Phase LCD RS485 Modbus RTU DIN 35mm AC 85-265V/ DC 100-350
- Acrel insulation monitoring device multiple fault indication function Mainly used in IT power distribution systems AIM-T300
- Acrel Residual current transformer is specially used for residual current signal collection AKH-0.66/L L-100*50II
- Acrel AKH-0.66/L L-150*130II Residual current sensor Can be used in conjunction with electrical fire monitoring devices, motor protection devices, etc.
- Acrel AKH-0.66/L L-180II current transformers Dedicated to residual current signal collection This product can output 5(2)mA twice
- Acrel AKH-0.66/L L-200*50II current sensor Dedicated to residual current signal collection This product can output 5(2)mA twice
- Acrel measuring rated current 250-400A low voltage leakeage CT Residual current transformer AKH-0.66/L L-100
- Acrel leakage current transformer rated current 400-800A Applied to residual current signal collection AKH-0.66/L L-150
- Acrel Motor Protection Relay ARD2F-1.6 Low Voltage DC4-20mA output with RS485 remote communication interface
- Acrel digital intelligent network Motor Protection Controller ARD2F-1With strong anti-interference ability
- Acrel DC4-20mA output ARD2F-5with RS485 remote communication interface, Smart Motor Protector
- Acrel Work stable and reliable DC4-20mA output Intelligent motor protector ARD2F-6.3
- Acrel Smart Motor Protector ARD2F-25 DC4-20mA output with RS485 remote communication interface
- Acrel Low Voltage Motor Protection Relay with RS485 remote communication interface ARD2F-250 , DC4-20mA output
- Acrel ARD2F-800 Provides the function of recording SOE fault events Intelligent motor protector
- Acrel Using CAN bus technology, insulation faults of 8 circuits can be located Insulation fault locator AIL150-8
- Acrel Accurately locate the circuit AIL150-4 Insulation fault locator where the insulation fault is located
Popular Searches
Recommended Products
- 8121FT-1 noise filter IEC60268-1 IEC60065 8121FT-1
- 152A IMPEDANCE METER 152a
- 139B Loudspeaker polarity tester 139B
- 7116C-60W Loudspeaker Acoustic Scanner
- 8121C white noise & pink noise tester 8121C
- 138A gauss meter and 138A probe sunlilab138A
- sunlilab white noise & pink noise tester 8121C
- 7116C-60W Loudspeaker Acoustic Scanner
- gauss meter and probe sunlilab138A
- 8121FT-1 noise filter IEC60268-1 IEC60065
- 152A IMPEDANCE METER
- 139B loudspeaker polarity tester
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Other Electrical Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile