![NANBEI INSTRUMENT LIMITED](https://img11.fr-trading.com/0/1_690_115930_600_600.jpg)
- NANBEI INSTRUMENT LIMITED
- China Manufacturer with main products:Laboratory Instrument ,Ice Maker ,Water Analysis Equipments ,Life Science Instruments ,Agricultural Instruments ,Chemical Analysis Equipments ,Thermal Cycler PCR ,Petroleum Instruments ,Drug Testing Equipment ,Physical Testing Instruments
Home > Products > testing instrument > Car Paint Ultrasonic Thickness Gauge Portable Coating Thickness Gauge
Car Paint Ultrasonic Thickness Gauge Portable Coating Thickness Gauge
- 1000 Set / Sets per Month
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 7 days
-
Rotovap Extractor Distillation Vacuum Laboratory Rotary Evaporator
-
Lab Distilling Machine Automatic Lifting Small Rotary Evaporator
-
Digital Temperature Control Laboratory Rotary Evaporator Kit Set
-
Ti-50 Digital Laboratory Automatic Potential Titrator Moisture Analyzer
-
High Precision Laboratory Benchtop pH Meter Water Tester PH300F
-
PHS Series Touch Screen Laboratory Digital Water pH Meter
Product Details
Brand Name: | NANBEI | Place of Origin: | China | Model Number: | CM10FN |
Product Description
CM10FN galvanized coating thickness gauge
Feature and Description
Magnetic induction principle (Fe): measuring steel, iron and other ferromagnetic metal substrate on the non-magnetic
coating thickness, such as paint layer, all kinds of anti-corrosion coating, paint, powder coating, plastic, rubber,
synthetic materials, Chromium, zinc, lead, aluminum, tin, cadmium and so on.
Eddy current principle (NFe): measurement of copper, aluminum, stainless steel and other non-ferromagnetic nature
of all non-conductive layer thickness, such as paint layer, all kinds of anti-corrosion coating, paint, powder coating,
plastic, rubber, synthetic materials, , Phosphating film and so on.
Standard Configuration
Standard configuration | Option |
CM10 Coating Thickness Gauge | Calibration film |
Calibration film | Aluminum plate zero plate |
Iron-based / aluminum-based zero plate | Iron-based zero plate |
Operation Manual | |
Two AA batteries | |
Certificate, packing list | |
Instrument box | |
Discs, data lines |
Technical data
Model | CM10FN | working principle | Magnetic induction |
Measuring range(um) | 0-10000 | Low resolution | 1 |
Test Conditions | Minimum radius of curvature(mm) | 10 | |
The smallest area of the diameter(mm) | 40 | ||
Matrix critical thickness(mm) | 2 | ||
Indication error(um) | ±(2%H+10) | ||
display | High contrast segment code LCD screen (LED backlight) | ||
Statistical function | The number of measurements, the maximum, the minimum, the average, the standard deviation | ||
Calibration method | Zero point, one point, two points calibration | ||
Operating temperature | -10℃ to +50℃ | ||
Automatic shut-down | 3 minutes after no operation automatically shut down | ||
power supply | Two 1.5V AA batteries, when the battery power is low, there is a low voltage prompt | ||
weight | Containing battery 200g | ||
size | 149mmX73mmX32mm(HxWxD) |
Model comparison
Model:CM10F
Application:
CM10F adopt magnetic measuring method to measure the thickness of non-magnetic coatings on magnetic metal
substrates.Widely used in electronics, power plants, petrochemical industry.,aviation, architecture,etc
Specification
Measuring Principle:Magnetic Method .
Measuring Principle (um) :P1(0~3000)
Low Range Sensitivity(um) :0.1
Tolerance:1-Point Calibration(um) :±(2%H+2)
2-Point Calibration(um) :±((1~3)%H+1)
Testing Condition:Min. Curvature Radius(mm):1.5
Min. Measuring Surface(mm): 7
Min. Substrate Thickness(mm): 0.5
Display:High Contrast Segment Liquid(LED Backlight)
Statistics:N,MAX,MIN,MEAN and STD.DEV
Calibration:One-Point Calibration and Two-Point Calibration
Working Temperature:-10℃~+50℃,-20℃ in special requirement.
Auto Power-off:Auto off after 3 minutes of inactivity.
Power:Two 1.5V AA batteries,low -voltage indication function.
Weight:200g including batteries
Size:149mm×73mm×32mm (H×W×D)
Model:CM10N
Application:
Using Eddy Current Measuring Method to measure the thickness of non-conductive coatings on non-magnetic
metal substrates. The Max. measuring range to 2000μm
Parameters:
Measuring Principle:Eddy Current Method
Measuring Range (um) :0~2000
Low Range Sensitivity (um) : 0.1
Tolerance:(um) ±(2%H+2)
Testing Condition:(mm): 3
Min. Measuring Suface(mm):5
min.Substrate Thickness(mm): 0.3
Display:Hight contrast Segment Liquid(LED backlight)
Statitics:N,MAX,MIN,MEAN,STD.DEV
Calibration:1-point Calibration,2-point Calibration
Working Temperature:-10℃~+50℃,-20℃ in special requirement
Auto Power-off:Auto off after 3 minutes of inactivity
Power:2 1.5V AA batteries,low-voltage indication function
Weight:200g including batteries
Size:149mm×73mm×32mm (H×W×D)
Model:CM10FH
Application:
Using the Magnetic Method (Fe) for Measuring the thickness of non- magnetic coatings on steel, iron and other
ferromagnetic metal substrates. Measuring Range is 0-10000μm.
Parameters:
Measuring Principle:Magnetic Method
Measuring Range (um) :(0~10000)
Low Range Sensitivity (um) :10
Tolerance::±(2%H+10)
Testing Condition:Min. Curvature Radius(mm):10
Min. Measuring Surface(mm): 40
Min. Suibstrate Thickness(mm): 2
Display:Hight Contrast Segment Liquid Crystal Display(LED Backlight)
Statistics:N,MAX,MIN,MEAN,STD.DEV
Calibration:One-point Calibration,Two-point Calibration
Working Temperature:-10℃~+50℃,-20℃ in special requirement
Auto Power-off:3Auto off after 3 minutes of inactivity
Power:Two 1.5V AA batteries,low-voltage indication function
Weight:200g including batteries
Size:149mm×73mm×32mm (H×W×D)
Model:CM10FN
Application:
This compact and handy pocket gauge has been designed for non-destructive, fast and precise coating thickness
measurement. Fit for both experiment and project site. According to the probe type, the gauge work either on the
magnetic induction principle or on the eddy currents principle
Parameters:
Working principle:P1 Magnetic Method ,P2 Eddy Current Method,
Measuring Range(um) :P1(0~3000), P2(0~2000), )
Low range sensitivity (um) :0.1( P1), 0.1(P2),
Tolerance:
One-point Calibration(um) :±(2%H+2) P1, ±(2%H+2)P2,
Two-point Calibration(um) :±((1~3)%H+1) P1, ±((1~3)%H+1.5)P2,
Testing Condition:
Min.Curvature Radius(mm):1.5 ( P1), 3(P2), 10(P3), 1(P4)
Min.Measuring Surface(mm): 7( P1), 5(P2), 40(P3), 3(P4)
Min.Substrate Thickness(mm): 0.5( P1), 0.3(P2), 2(P3), 0.2(P4)
Display: High Contrast Segment Liquid Crystal Display (LED Backlight)
Statistics: N, MAX, MIN, MEAN and STD.DEV
Calibration: One-point Calibration,Two-point Calibration
Auto Power-off: Auto off after 3 minutes of inactivity;
Power: 2AA 1.5V batteries,low-voltage indication function
Weight: 200g including batteries.
Size: 149mm×73mm×32mm (H×W×D)
Contact Us
- NANBEI INSTRUMENT LIMITED
- Contact namejenny
- Phone86-371-60310701
- AddressNo.72,Beihuan Road,Jinshui District Zhengzhou,Henan
-
Water Content Moisture Apparatus Automatic Karl FIscher Titrator
-
Optical Digital Spectrum Analyzer Portable Raman Spectrometer RAM785SP
-
Laboratory Intelligent Automatic WJL Series Laser Particle Size Analyzer
-
Laboratory Distillation Automatic Kjeldahl Nitrogen Analyzer
-
Agriculture Plant Growth Monitor Portable Laboratory Leaf Area Meter
-
High Precision Penetrating Coating Ultrasonic Thickness Gauge
-
Lab Table Type Water Quality Analyzer Benchtop Conductivity Meter
-
Laboratory Benchtop Digital Multiparameter Water Quality Analyzer
-
Laboratory Digital Torque Wrench Calibration Tester Machine ANBH
-
Lab Testing Equipment Electric Single Column Vertical Force Gauge Test Stand
-
Laboratory Measuring Instrument High Precision Digital Torsion Spring Tester
-
Physical Testing Digital Multi-range Torque Wrench Calibrator Tester
-
Physical Instrument Laboratory Portable Push Pull Force Gauge
-
Laboratory 7116M Desktop High-speed Centrifuge Machine
-
Small Jacketed Glass Reactor Double Layer Reaction Systems for Laboratory
-
Lab Jacketed Glass Reactor 10 Liter Chemical Reactor for Research
-
Mini Lab Jacketed Glass Reactor High Borosilicate Reaction Vessel
-
Customized Industrial Chemical Reaction Jacketed Glass Reactor
-
GG-17 Jacketed Glass Reactor Heating and Cooling Circulator Mixer Reactor
-
1-5L Single Layer Pyrex Borosilicate Tank Stirred Heated Glass Reactor
-
10L Digital Extraction Synthesis Laboratory Single Glass Reactor
-
Industrial Chemical 10L Jacketed Glass Reactor Pilot Plant Reactor
-
Laboratory Double Layer Jacketed Glass Chemical Reactor 30L
-
30L Chemical Bioreactor Hydrolysis Glass Reactor With Heating Bath
Popular Searches
Find Similar Products By Category
- Measurement & Analysis Instruments > Measuring & Gauging Tools > Gauges
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
jenny
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
-
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
Please input the mailbox.
-