Home > Products > Multifunction Power Meter > Durable and reliable Acrel APM830 three phase smart digital panel power meter/ multifunction programmable energy meter CE
Durable and reliable Acrel APM830 three phase smart digital panel power meter/ multifunction programmable energy meter CE
- 1000 Piece / Pieces per Month
- Shanghai
- T/T Credit Card
- High quality Acrel ADL400 din rail 3phase 4wire 220/380V energy meter for power consumption monitoring with MID certificate
- Acrel ADL3000-E multi tarrif three phase energy meter electric charging meter car 2 Channel RS485 Communication
- Customize Acrel ADL200 Single Phase 10(80)A Bidirectional Power meter/ Electric Energy Meter Multi Tariff Energies Optional
- Small-sized Acrel AHKC-EKA AC split open-loop hall effect current sensor Rated input:0-(50-500)A
- Energy saving Acrel AHKC-EKAA DC current sensor, output 4-20mA input 0~500A/hall sensor
- Convenient and user-friendly Acrel AHKC-EKDA hall effect sensor output 4-20mA input 0~500A
Product Details
Brand Name: | Acrel | Place of Origin: | China | Model Number: | APM830 |
Phase: | Three Phase | Output Voltage: | 10~230V phase voltage | Operating Temperature: | -20℃~65℃ |
Dimensions: | 96mm*96mm*88mm | Display Type: | Digital Only | Accuracy Class: | 0.5S class |
Measuring Energy Range: | 0-9999 |
Product Description
General
APM series meters have full power measurement, energy statistics, analysis of power quality and network communications and other functions, are mainly used for comprehensive monitoring of the quality of power supply network.
Technical Parameters | Index | |||
Signal | Electrical network | Three-phase three-wire, three-phase four-wire, see the wiring diagram; | ||
Frequency | 45~65Hz; | |||
Voltage | Rated value:AC 100V、110V、400V、690V; | |||
Overload: 1.2 times rated value(continuous); 2 times rated value /1 second; | ||||
Power consumption:<0.5VA (per channel); | ||||
Current | Rated value: AC 1A, 5A, support 4 mm2 line access; | |||
Overload: 1.2 times rated value(continuous); 10 times rated value/1 second; | ||||
Power consumption:<0.5VA (per channel); | ||||
Measurement accuracy | Voltage、current and power | class 0.5s/class 0.2s (APM800、APM810/APM801) | ||
Active power | class 0.5s/class 0.2s (APM800、APM810/APM801) | |||
Reactive power | class 2 | |||
Harmonic | 1%(2rd~42nd)、2%(43rd~63rd) | |||
Switch inputs | Dry contact inputs, built-in power supply; | |||
Relay outputs | Contact type: open contact in main part, changeover contact in module; Contact capacity:AC 250V/3A DC 30V/3A; | |||
Pulse output of energy | Output mode: Optocoupler pulse with open collector; Pulse constant:4000(5A)、8000(1A) imp/kWh; | |||
Analog outputs | DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V output, accuracy class 0.5%, load resistance ≤ 500Ω; | |||
Analog inputs | DC 0mA~20mA、4mA~20mA、0V~5V、1V~5V iutput, accuracy class 0.5% | |||
Storage card | Standard Capacity:4G,TF Card Up to 32G Capacity; | |||
Communication | RS485 interface/Modbus-RTU protocol and DLT645 protocol Profibus-DP interface/Profibus-DP protocol; RJ45 interface (Ethernet) / Modbus-TCP, http, DHCP and other protocols; | |||
Power supply | Working range: AC/DC 85V~265V or AC/DC 115~415V(P2); Power consumption: Power consumption of the main part ≤ 15VA; | |||
Safety | Power frequency withstand voltage | The power frequency withstand voltage between the shell and the auxiliary power supply, each input and output terminal group is AC 4kV/1min; The power frequency withstand voltage between the auxiliary power supply and each input and each output terminal group is AC 2kV/1min; The power frequency withstand voltage between the voltage input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the current input and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between the relay output and other input/output terminal groups is AC 2kV/1min; The power frequency withstand voltage between each terminal group of switch input, communication, analog output and pulse output is AC 1kV/1min; | ||
Insulation resistance | Inputs、outputs to the shell>100MΩ; | |||
Electromagnetic compatibility | Meet IEC 61000 standard (Level 4); | |||
Protection level | Display panel IP52 | |||
Environment | Operating temperature: -20 °C ~ +65 °C; Storage temperature: -20°C~+70°C; Relative humidity: ≤95% without condensation; Altitude: ≤2500m; | |||
Standards | IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 | Environmental Testing-Part 2-1:Tests Test A:Cold IDA Part 2-1:Tests Test B:Dry heat Part 2-30:Tests Test Db:Damp heat,cyclic(12+12h) | ||
IEC 61000-4 | Electromagnetic compatibility-Testing and measurement techniques | |||
IEC 61557-12 | Electrical safety in low voltage distribution system up to 1000V a.c. and1500V d.c –Equipment for testing,measuring or monitoring of protective measures- Part12: Performances measuring and monitoring devices(PMD) | |||
IEC 62053-22 | Electricity metering equipment (a.c.)-Particular requirements - Part22:Static meter for active energy(class 0.2s and 0.5s) |
Contact Us
- Jiangsu Acrel Electrical Manufacturing CO.,LTD
- Contact nameTim Chat Now
- Phone86-1870-6168051
- AddressJiangyin Wuxi,Jiangsu
Product Categories
- Acrel AHKC-EKB 0-(200-1000)A signal isolator transmitter hall effect current sensor/current transformer
- Acrel AHKC-EKBA 4-20mA hall sensor 24v output 4-20mA input 0~(200-1000)A
- AHKC-EKCA open-loop max dc input 1500A split core hall effect current sensor with 4 to 20mA output
- AHKC-K split open loop hall effect current transmitter AC/DC 0~(400~2000)A output 5V/4V power supply
- Acrel AHKC-KAA dc current sensor output 4-20mA input 0~(400-2000)A
- Hall current sensor/transducer Acrel AHKC-KDA AC current sensor AC0-(400-2000)A open loop transmitter
- Best selling Acrel AHKC-H dc current transducer output 5V/4V input 0~(500-3000)A
- large heavy current DC 0-25000-40000A input hall effect rectangle current transmitter transducer sensor AHKC-HBAA output 4-20mA
- BA05-AI/I(V) AC current transmitter din rail go through core/Input 0-10A/Output 4-20mA、0-20mA、1-5V、0-5V
- Acrel ADF400L 3 phase kwh meter din rail Multi Circuit Electrical Instruments 4 Channel 3 Phase Smart Energy Meter
- Acrel ADW300 Din rail smart electrical meter with rs485 modbus to monitor, collect and manage electricity
- Acrel ADW210 series CE approved Series IoT Wireless multi loop power meter 3P3W 3P4W with buttons and LCD display
- High quality Acrel AMC48-AI lighting cabinet digital ammeter
- Best selling Acrel AMC72L-AI3 3 phase LCD programmable current meter with RS485 modbus rtu
- AMC96L-E4/KC smart power collection and monitoring device power meter with RS485 4DI/2DO
- International standard Acrel 300286 panel DC power analyzer PZ72-DE
- Advanced Technology Acrel DJSF1352-RN RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate
- Precise Monitoring Acrel DJSF1352-RN/K RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/2DI/2DO
- Reliable Performance Acrel DJSF1352-RN/D RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel DC measurement
- Innovative Design Acrel DJSF1352-RN/2C RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel RS485
- Industry-Leading Support Acrel DJSF1352-RN/S RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/0.5S accuracy shunt connect
- Customizable 96*96mm Multifunction Power Analyser APM801/F Network power meter Multi Tariff Three Phase Energy Meter with muti tariff energies
- Versatile 96*96mm Multifunction Power Analyser APM801/MD82 Network power meter Multi Tariff Three Phase Energy Meter with 8DI+2DO
- User-friendly 96*96mm Multifunction Power Analyser APM801/MLOG Network power meter Multi Tariff Three Phase Energy Meter with SD card
Popular Searches
Recommended Products
- PIU2000A 0.01% Grade high precision DC Tester
- Industry-Leading Support Acrel DJSF1352-RN/S RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/0.5S accuracy shunt connect
- Innovative Design Acrel DJSF1352-RN/2C RS485 Modbus-RTU Communication Din Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel RS485
- Reliable Performance Acrel DJSF1352-RN/D Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/second channel DC measurement RS485 Modbus-RTU Communication
- Precise Monitoring Acrel DJSF1352-RN/K RS485 Modbus-RTU Communication Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate/2DI+2DO
- Acrel DJSF1352-RN Rail Type 2 Circuits DC Power Consumption Meter with CE,UL certificate RS485 Modbus-RTU Communication
- Acrel ADW300/L 1 channel of residual current measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/T 4 channel temperature measurement Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/K 4DI+2DO Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADW300/C Din rail smart electrical meter to monitor, collect and manage electricity with RS485
- Acrel ADW300 Din rail smart electrical meter to monitor, collect and manage electricity
- Acrel ADL3000-E multi tarrif three phase energy meter electric charging meter car 2 Channel RS485 Communication
Find Similar Products By Category
- Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Tim
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile