Home > Products > Invensys Triconex > Invensys Triconex 3625C1 Supervised/Non- Supervised Digital Output Modules
Invensys Triconex 3625C1 Supervised/Non- Supervised Digital Output Modules
- 50 Unit / Units per Month
- T/T
- Invensys Triconex 4000103-510 Output Cable Assy
- Allen-Bradley 1756-L62 100% Original in stock
- 1794-TB3S by ALLEN BRADLEY/ Module/Online sale
- Bently Nevada 3500/15-07-07-00 115M7750-01 High Voltage DC PIM
- Bently Nevada 3500/92 136188-02 Ethernet/RS485 Modbus I/O Module
- Bently Nevada 128031-01 Blank Filler Plate PLC Cover Module
Product Description
Manufacture | Invensys Triconex |
Model | Supervised/Non- Supervised Digital Output Modules |
Ordering information | 3625C1 |
Catalog | Tricon Systems |
Description | Invensys Triconex 3625C1 Supervised/Non- Supervised Digital Output Modules |
Origin | United States (US) |
HS Code | 85389091 |
Dimension | 16cm*16cm*12cm |
Weight | 0.8kg |
16-Point Supervised and
32-Point Supervised/Non-Supervised Digital Output Modules
Designed for the most critical control programs, supervised digital output (SDO) modules meet the needs of systems whose outputs remain in a single state for extended periods of time (in some applications, for years). An SDO module receives output signals from the main processors on each of three channels. Each set of three signals is then voted upon by a fully fault-tolerant quadruplicated output switch whose elements are power transistors, so that one voted output signal is passed to the field termination.
Each SDO module has voltage and current loopback circuitry coupled with sophisticated online diagnostics that verify the operation of each output switch, the field circuit and the pres-ence of a load. This design provides complete fault coverage without the need to influence the output signal.
The modules are called “supervised” because fault coverage is extended to include potential field problems. In other words, the field circuit is super-vised by the SDO module so that the following field faults can be detected:
• Loss of power or blown fuse
• Open or missing load
• A field short resulting in the load being energized in error
• A shorted load in the de-energized state
Failure to detect field voltage on any output point energizes the power alarm indicator. Failure to detect the presence of a load energizes the load alarm indi-cator.
All SDO modules support hot-spare modules and require a separate external termination panel (ETP) with a cable interface to the Tricon backplane.
Sumset International Trading Co., Limited
Parent company: Xiamen Hongxinhe Trading Co., Ltd.
Levi (Sales Manager/Technical Consultant)
Mobile (WhatsApp/Wechat): +86 18030030532
Email: sales13@htechplc.com
Website: /
Address: Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen, Fujian, China 361001
Contact Us
- Huge Technology Automation Co., Limited
- Contact nameLevi Chat Now
- AddressSiming Xiamen,Fujian
Bently Nevada | ABB | Allen Bradley |
- Bently Nevada 125388-01 Half-Height Chassis
- Bently Nevada 3500/15-06-06-00 114M5335-01 Low Voltage DC PIM
- Bently Nevada 3500/60 136711-01 RTD/TC I/O Module
- Bently Nevada 3500/70M 176449-09 Recip Impulse/Velocity Monitor
- Bently Nevada 330103-00-06-10-02-00 3300XL 8 Mm Proximity Probes Without Armour
- Bently Nevada 3500/45-01-00 135137-01 Position I/O Module With Internal Terminations
- Bently Nevada 3500/50-01-00 133442-01 I/O Module With Internal Terminations
- Bently Nevada 131178-01 3500 System Female To Female DB9 Cable
- Bently Nevada 3500/22M TDI 131170-01 Dynamic Data Transfer Cable
- Bently Nevada 128277-01 3500 Future Expansion PLC Blank Filler Plate
- Bently Nevada 128277-01 3500 Future Expansion PLC Blank Filler Plate
- Bently Nevada 128276-01 Half-Height Future Expansion
- Bently Nevada 128275-01 Slot Cover 3500 FUTURE EXPANSION
- Bently Nevada 3500/42M-01-00 128229-01 Prox/Seismic I/O Module With Internal Terminations
- Bently Nevada 3500/25-01-02-00 126648-01 Keyphasor I/O Module (External Terminations)
- Bently Nevada 3500/15-01-01-00 125840-02 Low Voltage Ac Power Input Module (PIM)
- Bently Nevada 3500/25-01-01-00 125800-01 Keyphasor I/O Module (Internal Terminations)
- Bently Nevada 3500/40-01-00 125680-01 Proximitor I/O Module
- Allen-Bradley 1756-L62 100% Original in stock
- 1794-TB3S by ALLEN BRADLEY/ Module/Online sale
- 1786-RPT by ALLEN BRADLEY/ Module/Online sale
- Original Packing Allen Bradley 1769-SDN DeviceNet Scanner Module
- Allen-Bradley 1756-DNB Module 100% Original in stock
- Powerful Allen Bradley Modules 1761-L32BWB MicroLogix 1000 24VDC 20DI-24VDC 12DO-RLY
Popular Searches
Recommended Products
- Allen Bradley 1747-M3 Memory Module 1747-M3 New arrival with best price
- Allen Bradley 1761-L16BWB MicroLogix 1000 Programmable Controllers
- Allen Bradley 1771-A3B1 I/O Chassis 1771-A3B1 New In Stock Original
- Allen Bradley 1771-IBD I/O Module 1771-IBD New arrival with best price
- Allen Bradley 1771-OBD Output Module 1771-OBD New Original Guarantee
- Allen Bradley 1734-OB8 POINT I/O Output Module 1734-0B8 In Origianl Packing
- Allen Bradley 1734-ADN POINT I/O DeviceNet Adapter 1734-ADN with good price
- Allen Bradley 1734-IB8 POINT I/O Input Modules 1734-IB8 Tested before shipping
- Allen Bradley 1734-IB8 POINT I/O Input Modules 1734-IB8 Tested before shipping
- Allen Bradley 1734-IB8S POINT Guard I/O Safety Modules 1734-IB8S in stock
- Allen Bradley 1734-MB POINT mounting base 1734-MB High Quality Well-Known Brands
- Allen Bradley 1734-RTB Terminal Block 1734-RTB New arrival with best price
Find Similar Products By Category
- Electronic Components & Supplies > Electronics Production Machinery
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Levi
Welcome to my shop! Glad to serve you!Please send your question!
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 20 to 5000 characters.Send Now.
-
*Email
Please input the mailbox.
-
Mobile